The range of domain IDs is from 1 to 1000.
2
Enter the port-channel number that acts as the interconnect trunk.
VLT DOMAIN CONFIGURATION mode
peer-link port-channel
id-number
3
Enter the VLAN ID number of the VLAN where the VLT forwards packets received on the VLTi from an adjacent peer that is down.
VLT DOMAIN CONFIGURATION mode
peer-down-vlan
vlan interface number
Configuring Enhanced VLT (Optional)
To configure enhanced VLT (eVLT) between two VLT domains on your network, use the following procedure.
For a sample configuration, refer to
. To set up the VLT domain, use the following commands.
1
Configure the port channel to be used for the VLT interconnect on a VLT switch and enter interface configuration mode.
CONFIGURATION mode
interface port-channel
id-number
Enter the same port-channel number configured with the
peer-link port-channel
2
Add one or more port interfaces to the port channel.
INTERFACE PORT-CHANNEL mode
channel-member
interface
interface
: specify one of the following interface types:
•
For a 1-GigabitEthernet interface, enter the keyword
GigabitEthernet
then the slot/port information.
•
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
then the slot/port information.
3
Enter VLT-domain configuration mode for a specified VLT domain.
CONFIGURATION mode
vlt domain
domain-id
The range of domain IDs is from 1 to 1000.
4
Enter the port-channel number that acts as the interconnect trunk.
VLT DOMAIN CONFIGURATION mode
peer-link port-channel
id-number
5
Configure the IP address of the management interface on the remote VLT peer to be used as the endpoint of the VLT backup link for
sending out-of-band hello messages.
VLT DOMAIN CONFIGURATION mode
back-up destination
ip-address
[interval
seconds
]
You can optionally specify the time interval used to send hello messages. The range is from 1 to 5 seconds.
6
When you create a VLT domain on a switch, Dell Networking OS automatically creates a VLT-system MAC address used for internal
system operations. To explicitly configure the default MAC address for the domain by entering a new MAC address, use the following
command.
VLT DOMAIN CONFIGURATION mode
system-mac mac-address
mac-address
Virtual Link Trunking (VLT)
903
Summary of Contents for S3048-ON
Page 1: ...Dell Configuration Guide for the S3048 ON System 9 11 2 5 ...
Page 137: ...0 Gi 1 1 Gi 1 2 rx Flow N A N A 0 0 No N A N A yes Access Control Lists ACLs 137 ...
Page 142: ...Figure 10 BFD Three Way Handshake State Changes 142 Bidirectional Forwarding Detection BFD ...
Page 241: ...Dell Control Plane Policing CoPP 241 ...
Page 287: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 287 ...
Page 428: ...Figure 53 Inspecting the LAG Configuration 428 Link Aggregation Control Protocol LACP ...
Page 477: ...Figure 73 Configuring Interfaces for MSDP Multicast Source Discovery Protocol MSDP 477 ...
Page 478: ...Figure 74 Configuring OSPF and BGP for MSDP 478 Multicast Source Discovery Protocol MSDP ...
Page 483: ...Figure 77 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 483 ...
Page 484: ...Figure 78 MSDP Default Peer Scenario 3 484 Multicast Source Discovery Protocol MSDP ...
Page 745: ...Figure 104 Single and Double Tag TPID Match Service Provider Bridging 745 ...
Page 746: ...Figure 105 Single and Double Tag First byte TPID Match 746 Service Provider Bridging ...