"NOT_REACHABLE: Syslog server
10.11.226.121 (port: 9140) is not reachable" SNMPv2-SMI::enterprises.6027.3.6.1.1.2.0 =
INTEGER: 2
Following is the sample audit log message that other syslog servers that are reachable receive:
Oct 21 00:46:13: dv-fedgov-s4810-6: %EVL-6-NOT_REACHABLE:Syslog server 10.11.226.121 (port:
9140) is not reachable
Following example shows the SNMP trap that is sent when connectivity to the syslog server is resumed:
DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (10230) 0:01:42.30 SNMPv2-MIB::snmpTrapOID.
0 = OID: SNMPv2-
SMI::enterprises.6027.3.30.1.1.2 SNMPv2-SMI::enterprises.6027.3.30.1.1 = STRING:
"REACHABLE: Syslog server
10.11.226.121 (port: 9140) is reachable"SNMPv2-SMI::enterprises.6027.3.6.1.1.2.0 = INTEGER: 2
Following is the sample audit log message that other syslog servers that are reachable receive:
Oct 21 05:26:04: dv-fedgov-s4810-6: %EVL-6-REACHABLE:Syslog server 10.11.226.121 (port: 9140)
is reachable
Copy Configuration Files Using SNMP
To do the following, use SNMP from a remote client.
•
copy the running-config file to the startup-config file
•
copy configuration files from the Dell Networking system to a server
•
copy configuration files from a server to the Dell Networking system
You can perform all of these tasks using IPv4 or IPv6 addresses. The examples in this section use IPv4 addresses; however, you can
substitute IPv6 addresses for the IPv4 addresses in all of the examples.
The following table lists the relevant MIBs for these functions are.
Table 73. MIB Objects for Copying Configuration Files via SNMP
MIB Object
OID
Object Values
Description
copySrcFileType
.1.3.6.1.4.1.6027.3.5.1.1.1.1.2
1 = Dell Networking OS file
2 = running-config
3 = startup-config
Specifies the type of file to copy
from. The range is:
•
If copySrcFileType is running-
config or startup-config, the
default copySrcFileLocation
is flash.
•
If copySrcFileType is a binary
file, you must also specify
copySrcFileLocation and
copySrcFileName.
copySrcFileLocation
.1.3.6.1.4.1.6027.3.5.1.1.1.1.3
1 = flash
2 = slot0
3 = tftp
4 = ftp
5 = scp
6 = usbflash
Specifies the location of source
file.
•
If copySrcFileLocation is FTP
or SCP, you must specify
copyServerAddress,
copyUserName, and
copyUserPassword.
copySrcFileName
.1.3.6.1.4.1.6027.3.5.1.1.1.1.4
Path (if the file is not in the
current directory) and filename.
Specifies name of the file.
774
Simple Network Management Protocol (SNMP)
Summary of Contents for S3048-ON
Page 1: ...Dell Configuration Guide for the S3048 ON System 9 11 2 5 ...
Page 137: ...0 Gi 1 1 Gi 1 2 rx Flow N A N A 0 0 No N A N A yes Access Control Lists ACLs 137 ...
Page 142: ...Figure 10 BFD Three Way Handshake State Changes 142 Bidirectional Forwarding Detection BFD ...
Page 241: ...Dell Control Plane Policing CoPP 241 ...
Page 287: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 287 ...
Page 428: ...Figure 53 Inspecting the LAG Configuration 428 Link Aggregation Control Protocol LACP ...
Page 477: ...Figure 73 Configuring Interfaces for MSDP Multicast Source Discovery Protocol MSDP 477 ...
Page 478: ...Figure 74 Configuring OSPF and BGP for MSDP 478 Multicast Source Discovery Protocol MSDP ...
Page 483: ...Figure 77 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 483 ...
Page 484: ...Figure 78 MSDP Default Peer Scenario 3 484 Multicast Source Discovery Protocol MSDP ...
Page 745: ...Figure 104 Single and Double Tag TPID Match Service Provider Bridging 745 ...
Page 746: ...Figure 105 Single and Double Tag First byte TPID Match 746 Service Provider Bridging ...