Dell PowerConnect B-Series TI24X Hardware Installation Guide
53-1002265-01
Replacing the fan tray
5
•
Installation precautions and warnings
•
Replacing the fan tray
Installation precautions and warnings
Follow these precautions when removing and installing a fan tray in the PowerConnect B-Series
TI24X .
CAUTION
Be careful not to accidently insert your fingers into the fan tray while removing it from the chassis.
The fan may still be spinning at a high speed.
CAUTION
Do not install the device in an environment where the operating ambient temperature might
exceed 40°C (104°F).
CAUTION
Never leave tools inside the device.
Removing the fan tray
Use the following procedures to remove the fan tray from PowerConnect B-Series TI24X devices.
shows the location of the fan tray.
FIGURE 22
PowerConnect B-Series TI24X fan tray location
1. Disconnect the PDU power cords (C13-C14) from the power supply.
NOTE
If the device is connected with two Power supplies, you need to disconnect both the PDU power cords
(C13-C14) from the device.
1
Fan Tray
1