119
Function
Code
Parameter
Name
Setting Range
Minimum
Unit
Default
Property
E0.00
User-defined
function code 0
P0.01
~
PE.xx
-
P0.01
○
E0.01
User-defined
function code 1
P0.01
~
PE.xx
-
P0.02
○
……
……
……
……
……
○
E0.06
User-defined
function code 6
P0.01
~
PE.xx
-
P0.18
○
E0.07
~
E0.31
User-defined
function code 7
~
31
P0.01
~
PE.xx
-
P0.02
○
Group b: Standard Monitoring Parameters
Function
Code
Parameter Name
Setting Range
Minimum
Unit
Default
Property
b0.00
Running
frequency
(
HZ
)
0.00Hz
~
P0.02Hz
0.01Hz
7000H
b0.01
Setting
frequency
(
HZ
)
0.00Hz
~
P0.02Hz
0.01Hz
7001H
b0.02
Bus voltage
(
V
)
0.0V~1000.0V
0.1V
7002H
b0.03
Output voltage
(
V
)
0V~380V
1V
7003H
b0.04
Output current
(
A
)
0.01A
~
655.35A
0.01A
7004H
b0.05
Output power
(
KW
)
0.0kw~1000.0kw
0.1KW
7005H
b0.06
Output torque
(
%
)
0.0%~200.0%
0.1%
7006H
b0.07
DI input status
H.0000~H.FFFF
1
7007H
b0.08
DO output status
H.0000~H.FFFF
1
7008H