This function is valid when motor 1 is selected and acceleration/deceleration time
switchover is not performed by means of DI terminal. It is used to select different groups of
acceleration/deceleration time based on the running frequency range rather than DI terminal
during the running process of the AC drive.
Figure 6-12 Acceleration/deceleration time switchover
During acceleration, if the running frequency is smaller than the value of P2.23, acceleration
time 2 is selected. If the running frequency is larger than the value of P2.23, acceleration
time 1 is selected.
During deceleration, if the running frequency is larger than the value of P2.24, deceleration
time 1 is selected. If the running frequency is smaller than the value of P2.24, deceleration time
2 is selected.
P2.25
Terminal JOG preferred
Setting Range
:
0.
~
1
0
0
:
Disabled
;
1
:
Enabled