220
Pb.19
Acceleration/deceleration time of
simple PLC reference 0
Setting Range: 0
~
3
0
Pb.20~46
(even)
Running time of simple PLC
reference n
Setting Range:
0.0s(h)
~
6553.5s(h)
0.0s(h)
Pb.21~46
(singular)
Acceleration/deceleration time of
simple PLC reference n
Setting Range: 0
~
3
0
P b.48
Running time of simple PLC
reference 15
Setting Range:
0.0s(h)
~
6553.5s(h)
0.0s(h)
Pb.49
Acceleration/deceleration time of
simple PLC reference 15
Setting Range: 0
~
3
0
Pb.50
Time unit of simple PLC running
Setting Range: 0
~
1
0
0: s(second)
;
1: h(hour)
P b.51
Reference 0 source
Setting Range: 0
~
5
0
0
:
set by PA.00
;
1
~
2: VI
、
CI
;
4
:
PULSE setting
;
5
:
PID
;
6
:
Set by preset
frequency
It determines the setting channel of reference 0. You can perform convenient switchover
between the setting channels. When multi-reference or simple PLC is used as frequency
source, the switchover between two frequency sources can be realized easily.
6.13 Communication Parameter
(
Group PC
)
Please refer to chapter 9
YX-9000 RS485 communication protocol
6.14 Function Code Parameter
(
Group Pd
)
Pd.00
User password
Setting Range:
0