174
frequency of the AC drive reaches the upper limit or lower limit, the terminal becomes ON.
15
:
Ready for RUN
If the AC drive main circuit and control circuit become stable, and the AC drive detects no
fault and is ready for RUN, the terminal becomes ON.
16
:
VI larger than CI
When the input of VI is larger than the input of CI, the terminal becomes ON.
17
:
Frequency upper limit reached
If the running frequency reaches the upper limit, the terminal becomes ON.
18
:
Frequency lower limit reached (no output at stop)
If the running frequency reaches the lower limit, the terminal becomes ON. In the stop state,
the terminal also becomes ON.
19
:
Under-voltage state output
If the AC drive is in under-voltage state, the terminal becomes ON.
20
:
Communication setting
DO output controlled by communication setting, refer to the communication protocol in
chapter nine.
22
:
Accumulative running time reached
If the accumulative running time of the AC drive exceeds the time set in P2.16, the terminal
becomes ON.
23
:
Zero-speed running 2 (having output at stop)