Electrical Input Connection
Do not connect 110-120 VAC to the gas control valve or control system of this fireplace.
The electrical line to the grounded harness inside the fireplace must be installed by a qualified
installer and must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical connection. Turn the
breaker on only after all wiring is in place (power vent, on-off LED harness, etc.).
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The electrical line must supply 120 Volts, 60 Hz, and 7 Amps (maximum draw). We recommend a
dedicated circuit for the fireplace.
Route the electrical connection through the cover plate and attach to the electrical input wires as
shown below.
Make sure to connect the incoming ground wire to both ground wires
(one
ground wire attaches to the junction box, the other leads to the molex connector).
Caution
:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
HINT
: Keep the high voltage (120ac) cover plate disconnected until the power vent power lead is
attached. Leave the romex clamps loose until the cover plate is re-attached.
Optional Heat
Exchanger Connection
Power Vent
1/4" Nutdriver
High Voltage (120vac)
Cover Plate
Romex Clamp
Power In
Ground Wire