Installation
(for qualified installers only)
73
© Travis Industries
6/19/18 - 1418
DaVinci-Cat2+
Louvered Termination (used for intake(s) or exhaust vent)
NOTE
: Similar louver designs may be used at the discretion of the manufacturer, following confirmation of
the certifying body.
The Louver Requires an Adapter – see the following page.
Packing List:
•
Louvered Termination, Mounting Flange (w siding ledge), Mounting Flange (no ledge), (12) Self
Drilling #8 x ½” Screws
Dimensions
Painting the Louvered Termination and Flange(s)
The exterior surfaces have been treated (chromate) to optimize paint adhesion. This treatment
leaves the aluminum a bronze color. Use a suitable outdoor primer and finish coat on this surface as
desired. NOTE: If used as an exhaust termination, use paint capable of withstanding 400° F. (e.g.:
Stove Bright).
Installation Considerations
This termination must be placed horizontally.
The termination, when used as an exhaust, has a 1/2” clearance to combustibles (use included
mounting flange for combustible framing)
The included mounting flanges may be secured to the louvered termination using the included
screws. Use the flange best suited for your installation.
20"
508mm
16.75"
426mm
7.25"
185mm
Louvered Termination
(external view)
Louvered Termination
(internal view)
Mounting Flange (with siding ledge)
Mounting Flange (no ledge)
23-5/8"
601mm
20-3/8"
518mm
1-1/4"
32mm
22-1/4"
566mm
25-1/2"
648mm
23-5/8"
601mm
20-3/8"
518mm
UP
1/2" Clearance
1/2" Clearance
1/2" Clearance