Installation
(for qualified installers only)
57
© Travis Industries
6/19/18 - 1418
DaVinci-Cat2+
Connecting the Power Vent Lead to the Fireplace
The power vent is wired to the 120v line exiting the exhaust blower rheostat. Connect a minimum 12
gauge sheathed three-wire electrical line to the power vent lead (labeled “POWER VENT”) and
connect it to the molex connector on the fireplace – see illustration below. This wire is routed to the
power vent assembly (see “Wiring the Power Vent Assembly” for details).
After attaching the vent power lead, re-attach the high voltage (120ac) cover plate then tighten the
romex clamps to secure the wiring.
Optional Heat
Exchanger Connection
Power Vent
1/4" Nutdriver
High Voltage (120vac)
Cover Plate
Romex Clamp
Re-attach the high voltage (120ac)
cover plate then tighten the romex
clamps to secure the wiring.
Power Vent Lead