![DaVinci Category 2 Owner'S Manual Download Page 45](http://html1.mh-extra.com/html/davinci/category-2/category-2_owners-manual_514630045.webp)
Installation
(for qualified installers only)
45
© Travis Industries
6/19/18 - 1418
DaVinci-Cat2+
Typical Framing Dims. – Full Bay Configuration
Recessing the Back Edge of the Fireplace (Optional)
Installers may wish to recess the back of the fireplace to allow for a more shallow installation, placing
the side glass next to the side wall(s). If you decide to recess the back of the fireplace, make sure to
accommodate the framing and facing dimensions. The back edge of the glass extends to a location
5.75” (147mm) from the back of the fireplace (see dimensions page for details). Framing for this type
of installation may protrude forward from the back wall of the opening a maximum of 5.25” (134mm)
when using ½” (13mm) drywall. Consult the dimensions page and plan your installation prior to
framing the opening.
Version
Width (x)
Height (y)
12” Glass
Height (y)
20” Glass
Height (y)
30” Glass
Height (y)
36” Glass
Height (y)
58” Glass
Category 2
84” Full Bay
84.125” (2137mm)
50.625”
(1286mm)
58.625”
(1490mm)
68.625”
(1744mm)
74.625”
(1896mm)
96.625”
(2455mm)
96” Full Bay
96.125” (2442mm)
108” Full Bay
108.125” (2747mm)
120” Full Bay
120.125” (3052mm)
132” Full Bay
132.125” (3356mm)
Category 3
144” Full Bay
144.125" (3661mm)
156” Full Bay
156.125" (3966mm)
168” Full Bay
168.125" (4271mm)
180” Full Bay
180.125" (4576mm)
192” Full Bay
192.125" (4880mm)
Max. 5.25"
134mm
y
19.75"
502mm
x
The framing above the fireplace must be self-
supporting (the fireplace is not load-bearing).
3" (77mm) Maximum for vent clearance. Do not place
vertical framing directly in the center above the fireplace -
it will infringe upon the vent clearance requirements.