22
Installation
(for qualified installers only)
© Travis Industries
6/19/18 - 1418
DaVinci-Cat2+
Category 3 Order of Install
1. Prepare the installation location.
NOTE
: We recommend leaving the framing near the master module open. This allows for fireplace placement
and hookup. At a minimum, we recommend 12” of open area to the side of the master module.
2. Install the alignment track (see page 24).
NOTE
: Category 3 fireplaces use 3 tracks and 2 joining sections. Start at one end and attach the tracks together
using the joining sections. NOTE: The track is symmetrical and the sections do not need to be placed in any
specific order (e.g. 3’ + 5’ + 5’ is the same as 5’ + 3’ + 5’).
3. Module placement order and connection process.
a) Place the end secondary module on the alignment track (this is the module that is farthest away from the
master module). Make sure it is in its final location (see page 25).
b) Place the middle module on the alignment track with 12” of separation to the end secondary module.
c) Remove the adjacent shipping end caps from the two secondary fireplace modules (see page 25). Remove
components to allow for fireplace joining (see page 26).
d) Join the two secondary modules together:
- Slide modules together (see page 29)
- Install upper titan lock brackes (
do not tighten
- see page 30)
- Install lower titan lock braces (
do not tighten
- see page 31)
- Place adjustable alignment tool in center of opening – adjust as necessary (see page 32)
- Attach tension rods between the two secondary modules -
do not tighten
(see page 33)
e) Make sure the two secondary modules are in their final position (adjust/slide as necessary).
f) Place the master module on the alignment track with approximately 12” of separation to the middle module.
g) Remove the remaining shipping end caps from the fireplace modules (see page 25). Remove components to
allow for fireplace joining (see page 26).
h) Join the remaining modules together:
- Slide modules together (see page 29)
- Install upper titan lock brackes (
do not tighten
- see page 30)
- Install lower titan lock braces (
do not tighten
- see page 31)
- Place adjustable alignment tool in center of opening – adjust as necessary (see page 32)
- Attach tension rods between the primary and secondary modules (see page 33)
i) Tighten the tension rods (see page 33).
j) Tighten the titan locks (see page 34)
k) Remove alignment tool – verify alignment (see page 34)
4. Secure the fireplace to the alignment track (see page 35).
5. Attach the gas and electrical lines between the fireplace modules (see page 37).
6. Install the pressure switch tube (see page39).
6. Install the periphery components:
a) Install the vent (and power vent blower assembly).
b) Install the air intake(s).
c) Install the gas line.
d) Install the electrical line, on/off switch, and LED controller.
7. Test operation of the fireplace before attaching facing or drywall (this can be done with no crushed glass
and the outer glass pane(s) removed). This allows the installer to verify all connections and diagnose
issues with the fireplace exterior accessible.
a) Adjust the air shutters (if needed)
b) Adjust the exhaust blower (if needed)
c) Shut the fireplace off. Install the outer the glass pane(s).
d) Re-start the fireplace and test glass pane temperature (allow fireplace to burn 2 hours)
8. Frame the area around the fireplace.
9. Install the drywall and/or facing.
10. Install the hearth (if applicable). Install the mantel (if applicable).
11. Finalize the installation (see page 96).