DT9100 B
7.8.
Synchronisation gate time
(06. menu item)
Function
The setting of the pulse width of the remote
synchronisation signal. When the active state of the
synchronising pulse is lower then this value the instrument
will not accept it as a synchronisation pulse (this function is
useful for filtering a false pulse caused by noise). The
active state of the pulse is low (closed contact
R < 1 kΩ. between contacts 7 and 8 at the synchronisation
terminals).
When the pulse is in a low state the clock stops (and you
will see the
mnemonic on the display), and when
the pulse goes to a high state, the clock starts (and you will
see the time on the display).
Sequence of operations
1. Enter the menu by typing in the supervisor code.
The way the code should be typed in is described in
Chapter 7.1. Type in the code (password)
You will see on
the display:
.
2. Keep stepping by pressing the ▲ button until the menu
item
.
3. Enter the menu item by pressing the
ENTER
button.
4. You will see the actual gate time on the display, and the
first digit will be blinking.
5. By pressing button ▲ you can set the pulse width
between 1 and 8 seconds.
Exit from the menu item
1. After finishing the setting, press the
MENU
button to exit
the menu item, and you will see this:
.
(2. If you want to change the setting you have just done, or
if you just want to check what you have typed in, go on with
the operation from point 3 of the
Sequence of
operations
.)
(3. If you don’t want to exit the menu, as you want to do
further settings, then you may select the desired menu
items by pressing the ▲ button.)
Exit from the menu
1. Press the
MENU
button. First the mnemonic
(
Save
), then the mnemonic
(
Exit
) are shown on the
display. With this the storing of the settings is completed.
The instrument has exited the menu and goes on with the
measurement.
20180905-V1
37
Summary of Contents for DT9100 B
Page 1: ...DT9100 B Intrinsically Safe Digital Clock Operating Instructions...
Page 47: ...DT9100 B 10 2 Application example 20180905 V1 47...
Page 56: ...DT9100 B 10 8 ATEX Certification 56 20180905 V120180905...
Page 57: ...DT9100 B 20180905 V1 57...
Page 58: ...DT9100 B 58 20180905 V120180905...
Page 59: ...DT9100 B 20180905 V1 59...
Page 60: ...DT9100 B 60 20180905 V120180905...
Page 61: ...DT9100 B 20180905 V1 61...
Page 62: ...DT9100 B 62 20180905 V120180905...