D-500 MK2 User Manual Firmware V-6.3
- 131 -
Parameter Definition
Factory Set
Description
Mail Account Name
d500_a
This is the account name appearing in the
“
from
” tab
of the e-mail recipient. (ex: [email protected])
Mail Account
Password
d500_1234
This is the e-mail password of above e-mail account.
Mail Server Address
smtp.mail.yahoo.com
This is the Outgoing Mail Server Address of the above
e-mail account (ex: smtp.gmail.com)
E-mail Address-1
E-mail Address-2
E-mail Address-3
-
-
-
These are e-mail recipient addresses where the unit is
intended to send e-mail messages. Up to 3 e-mails can
be sent at once.
Parameter Definition
Unit
Min
Max
Factory
Set
Description
Web Programming
Enable
-
0
1
0
0:
Web programming disabled
1:
Web programming enabled
Web Control Enable
-
0
1
0
0:
Web control disabled
1:
Web control enabled
Web Refresh Rate
sec
0
240
5
The unit will refresh the web page with
this interval.
Ping Period
min
0
240
0
The unit will check the availability of the
internet connection with this interval.
Rainbow Refresh Rate
sec
0
65535
5
The unit will update the distant
monitoring terminal with this rate.
Rainbow Address-1 Port
-
0
65535
0
This is the port number of the first
monitoring terminal address.
Rainbow Address-2 Port
-
0
65535
0
This is the port number of the second
monitoring terminal address.
Web Server Port
-
0
65535
80
This is the port number of the internal
web server. The unit will answer queries
to this port only.
Modbus TCP/ Port
-
0
65535
502
This is the port number of the internal
Modbus TCP/IP terminal. The unit will
answer Modbus requests to this port
only.
SMTP Port
-
0
65535
587
This is the port number used for e-mail
sending.
Ethernet Enable
-
0
1
1
0:
ethernet port disabled
1:
ethernet port enabled
E-mail on IP Change
-
0
1
0
This parameter controls e-mail sending
when IP address of GPRS or ethernet
connection is changed. No warnings
generated.
0:
no e-mail on IP change
1:
e-mail sent on IP change
17.14. ETHERNET PARAMETERS (continued)
Below ETHERNET related parameters are found in the
Controller Configuration group.
Summary of Contents for D-500 MK2
Page 40: ...D 500 MK2 User Manual Firmware V 6 3 40 5 3 3 PHASE 3 WIRE DELTA 5 2 3 PHASE 4 WIRE STAR ...
Page 54: ...D 500 MK2 User Manual Firmware V 6 3 54 7 2 MAINS SYNCHRONIZATION FUNCTIONALITY ...
Page 55: ...D 500 MK2 User Manual Firmware V 6 3 55 7 3 SINGLE GENSET PARALLEL WITH MAINS FUNCT ...
Page 56: ...D 500 MK2 User Manual Firmware V 6 3 56 7 4 AMF FUNCTIONALITY ...
Page 57: ...D 500 MK2 User Manual Firmware V 6 3 57 7 5 ATS FUNCTIONALITY ...
Page 58: ...D 500 MK2 User Manual Firmware V 6 3 58 7 6 REMOTE START FUNCTIONALITY ...
Page 59: ...D 500 MK2 User Manual Firmware V 6 3 59 7 7 ENGINE CONTROL FUNCTIONALITY ...
Page 60: ...D 500 MK2 User Manual Firmware V 6 3 60 7 8 REMOTE DISPLAY PANEL FUNCTIONALITY ...