DM16E1 / DM4E1 Operation and Installation Manual - 204-4001-19
44
−
Sync. OK: Receiving data.
−
Rec. AIS: Receiving AIS (data always in marker signal).
−
LOS: Electric signal absent or below the minimum specified.
4.11. Tests
The screen below shows the test menu for E1 tributaries.
#
-------------------------------------------------------------------------
#
DataCom Telematica - DM16E1 Multiplexer
#
/local/test/ports/E1
#
-------------------------------------------------------------------------
#
Test functions
#
Slot 3 - Port 01 - E1 tributary Ports (16)
#
#
#
Test Function :[ None ]
#
#
#
#
#
#
1 - None
#
2 - Start LDL
#
3 - Start LAL
#
#
Option: [ ]
#
-------------------------------------------------------------------------
#
<ESC> Return to Previous Menu
#
<PgUp> Pre[V]ious Card [N]ext Port <PgDn>
#
-------------------------------------------------------------------------
In order to activate tests in a specific port, both the port and the test activation must be enabled (see
chapter 4.9.1).
The options 1) None, 2) Start LDL and 3) Start LAL select the active test.
Note that the activation of an LDL/LAL test in the remote unit functions as a remote loopback, and may
serve as a test for the local interface (for example, inserting BERT in a E1 channel).
For further detail about the test operation mode, see chapters 4.7 and 4.8