background image

Pantron Automation, Inc.   •   P.O. Box 6039   •   Gastonia, NC 28056   •   Phone: 800-211-9468   •   Fax: 704-864-0120

Photo-electric Multiplexer IMX-A832I 

(Industrial Module)

8-channel automatic Multiplexer

•

Multichannel amplifier with modulated infrared

light

•

8-channel installation system for tight assembly

without cross-talk

Automatic level control (ALC) according to

assembly distance and direction

•

Range up to 25 m (82 ft)

•

One transistor output for each channel (npn/pnp)

•

Test function to check installation and signal

strength

•

Switching mode light/dark selectable for each

channel

•

Basic transmit level selectable for each channel

•

Master-Slave mode

•

Transmitter and receiver connections are short-

circuit proof

Description

The 8-channel automatic multiplexer from Pantron

is a processor controlled amplifier with an integrated

analysis unit. Up to eight transmitters and receivers

can be connected to each unit without possibility of

cross talk. The amplifier works with modulated

infrared light which provides high immunity to ambient

light. The automatic gain setting enables the user to

simplify the installation and work.

For each channel, the multiplexer has one transistor

output (pnp/npn) and a yellow status LED.

All channels can be switched independent from each

other to different working conditions by DIP-switches.

The sensitivity of the device can be switched to 4

basic transmit levels using the same method. Also,

the transmitter power can be increased to optimize

object recognition.

A control unit, which can be activated by simply

pressing a button, is used to determine malfunctions

in the transmitter or the receiver. If nothing is

defective, the test function shows the signal quality.

A line display shows the received signal intensity. The

l

e

d

o

M

C

D

V

4

2

/I

2

3

8

A

-

X

M

I

Safety Instructions

The operation of infrared multiplexer IMX... is not

authorized for applications where safety of person

depends on the device function.

more flashes received, the stronger the signal.

If more than 8 channels are required, several 8-

channel automatic multiplexers or 8-channel standard

multiplexers can be synchronized via master-slave

operation.

An alarm display and output, which shows errors and

the limit of the transmit power and is connectable

with a PLC, enables users to safely work with the

photo-electric multiplexer.

Ordering Guide

Summary of Contents for IMX-A832I

Page 1: ...ser to simplify the installation and work For each channel the multiplexer has one transistor output pnp npn and a yellow status LED All channels can be switched independent from each other to different working conditions by DIP switches The sensitivity of the device can be switched to 4 basic transmit levels using the same method Also the transmitter power can be increased to optimize object reco...

Page 2: ...L x 8 t u p t u o r o t s i s n a r T p n p n p n y a l p s i d e d o m n o i t a r e p O x a m a t a d g n i h c t i w S C D V 0 3 2 1 A m 0 0 1 e d o m l a m r o N n e e r g D E L T e m i t n o i t c a e R N O T F F O s m 3 3 s m 3 3 e d o m t s e T w o l l e y D E L y c n e u q e r f g n i h c t i w S z H 5 1 y a l p s i d e d o m e v a l S w o l l e y D E L t u p t u o m r a l A p n p n o i t ...

Page 3: ...lation using short connecting cables Transistor output NPN PNP yellow black Output Receiver Transmitter 24VDC 1 2 3 4 5 6 8 7 IR Transmitter IR Receiver black black black black black black black Voltage Supply Ground Transistor output 1 2 3 4 5 6 7 8 Master OUT from master Slave IN following slave devices Alarm output PNP yellow yellow red red red red yellow Output Transmitter 24VDC RL external po...

Page 4: ...d 1 yellow 2 yellow 3 yellow 4 yellow 1 8 green 1 8 red STATUS STATUS MEANING MEANING 8 CHANNEL INFRARED AUTOMATIC MULTIPLEXER 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 picture 1 Numbers of terminals a Voltage Supply V SUPPLY 1 Before connecting the multiplexer look on the side and check if the power supply is the same as the connection v...

Page 5: ...odes a Normal mode This is the standard mode that is implemented after switching the supply voltage on as well as after the RESET push button has been pressed b Test mode This mode is used for the physical alignment of the sensor heads and to test the set up and wiring The multiplexer displays the following information Signal strength Sensor error selected basic transmit level The sensor heads are...

Page 6: ...mitter 24VDC Normal Operation Mode Test Operation Mode 1 8 green 1 red 2 red 1 yellow 2 yellow 3 yellow 4 yellow 1 8 green 1 8 red STATUS STATUS MEANING MEANING 8 CHANNEL INFRARED AUTOMATIC MULTIPLEXER H1 H10 H2 H11 H3 H12 H4 H13 H5 H14 H6 H15 H7 H16 H8 H17 H9 H18 S1 S2 DIP 1 DIP 2 DIP 3 1 h c t i w S P I D 2 h c t i w S P I D 3 h c t i w S P I D e d o m g n i h c t i w s 1 r e w o p t i m s n a r...

Page 7: ...after the other The information interrupt or clearence transmit power etc are evaluated and the state of the displays and transistor outputs are continuously shown The displays H1 to H8 OUTPUT STATUS 1 indicate the state of the outputs H10 to H17 AUTOMATIC FUNCTION 1 indicate the state of the Automatic Level Control If the beam is made between the transmitter and receiver of one channel the AUTOMA...

Page 8: ...ing S2 RESET 1 or after a few seconds without pressing the buttons the device goes back to the normal operation mode Beam status The display H10 to H17 indicates information about the beam quality resp errors at the sensor heads If nothing is defective H10 to H17 indicates the signal strength of the selected channel The more green LED s are visible the better the received signal is Use this option...

Reviews: