0-13 Readout: Linked Set-ups
Array [5]
Range:
Function:
0
*
[0 -
255 ]
View a list of all the set-ups linked by means of
. The parameter has one index for each
parameter set-up. The parameter value displayed for
each index represents which setups are linked to that
parameter setup.
Index
LCP value
0
{0}
1
{1,2}
2
{1,2}
3
{3}
4
{4}
Table 3.2 Example: Set-up 1 and Set-up 2 are linked
0-14 Readout: Prog. Set-ups / Channel
Range:
Function:
0
*
[-2147483648 -
2147483647 ]
View the setting of
for each of the four different communication
channels. When the number is displayed in
hex, as it is in the LCP, each number
represents one channel.
Numbers 1-4 represent a set-up number; ‘F’
means factory setting; and ‘A’ means active
set-up. The channels are, from right to left:
LCP, FC-bus, USB, HPFB1.5.
Example: The number AAAAAA21h means
that the FC-bus selected Set-up 2 in
, the LCP selected
Set-up 1 and all others used the active set-
up.
3.2.3 0-2* LCP Display
Define the variables displayed in the Graphical Local Control
Panel.
NOTE
Please refer to
,
and
for information on how to write display
texts.
0-20 Display Line 1.1 Small
Option:
Function:
Select a variable for display in line 1,
left position.
[0]
*
None
No display value selected
[37]
Display Text 1
Enables an individual text string to
be written, for display in the LCP or
to be read via serial communication.
0-20 Display Line 1.1 Small
Option:
Function:
[38]
Display Text 2
Enables an individual text string to
be written, for display in the LCP or
to be read via serial communication.
[39]
Display Text 3
Enables an individual text string to
be written, for display in the LCP or
to be read via serial communication.
[89]
Date and Time
Readout
Displays the current date and time.
[953]
Profibus Warning
Word
Displays Profibus communication
warnings.
[1005]
Readout Transmit
Error Counter
View the number of CAN control
transmission errors since the last
power-up.
[1006]
Readout Receive
Error Counter
View the number of CAN control
receipt errors since the last power-
up.
[1007]
Readout Bus Off
Counter
View the number of Bus Off events
since the last power-up.
[1013]
Warning
Parameter
View a DeviceNet-specific warning
word. One separate bit is assigned to
every warning.
[1115]
LON Warning
Word
Shows the LON-specific warnings.
[1117]
XIF Revision
Shows the version of the external
interface file of the Neuron C chip on
the LON option.
[1118]
LonWorks Revision Shows the software version of the
application program of the Neuron C
chip on the LON option.
[1501]
Running Hours
View the number of running hours of
the motor.
[1502]
kWh Counter
View the mains power consumption
in kWh.
[1600]
Control Word
View the Control Word sent from the
frequency converter via the serial
communication port in hex code.
[1601]
Reference [Unit]
Total reference (sum of digital/
analog/preset/bus/freeze ref./catch
up and slow-down) in selected unit.
[1602]
*
Reference [%]
Total reference (sum of digital/
analog/preset/bus/freeze ref./catch
up and slow-down) in percent.
[1603]
Status Word
Present status word
[1605]
Main Actual Value
[%]
View the two-byte word sent with
the Status word to the bus Master
reporting the Main Actual Value.
[1609]
Custom Readout
View the user-defined readouts as
defined in
,
Parameter Description
VLT
®
HVAC Drive Programming Guide