Number
Description/connector name
Name on
corresponding
connector
Number
Description/connector name
Name on
corresponding
connector
1
Local control panel (LCP)
–
18
Hybrid cable line 2
–
2
Front cover
–
19
Decoupling plate
–
3
STO 1 IN: STO
(Used for STO input voltage 1)
+STO–
20
Shielded cable grounding
clamp and strain relief
–
4
STO 1 IN: 24 V
(Used for bridging when the STO function
is not required, see
)
+24V–
21
24/48 V IN
(Auxiliary input terminal)
+AUX–
5
LEDs for status of auxiliary output and
STO
–
22
Relay 1
Relay 1
6
Decoupling clamp for STO cable
–
23
Relay 2
Relay 2
7
ISD Line 2: STO 2
(STO output to hybrid cable line 2)
+STO–
24
Brake
R– (81), R+ (82)
8
ISD Line 2: NET 2 X4
(Ethernet output to hybrid cable line 2)
RJ45 connector
(without label)
25
Mains
(Input terminal)
L1 (91), L2 (92), L3
(93)
9
ISD Line 2: AUX 2
(Auxiliary output to hybrid cable line 2)
+AUX–
26
Decoupling fixture for Ethernet
inputs
–
10
ISD Line 2: UDC 2
(UDC output to hybrid cable line 2)
+UDC–
27
Decoupling clamp for encoder
cable
–
11
ISD Line 1: STO 1
(STO output to hybrid cable line 1)
+STO–
28
X1
(Ethernet input line 1)
RJ45 connector
(not included)
12
ISD Line 1: NET 1 X3
(Ethernet output to hybrid cable line 1)
RJ45 connector
(without label)
29
X2
(Ethernet input line 2)
RJ45 connector
(not included)
13
ISD Line 1: AUX 1
(Auxiliary output to hybrid cable line 1)
+AUX–
30
GND, 24 V, GX, /RS422 TXD,
RS422 TXD, /RS422 RXD, RS422
RXD
(Encoder terminal)
Not labeled
14
ISD Line 1: UDC 1
(UDC output to hybrid cable line 1)
+UDC–
31
STO 2 IN: STO
(Used for STO input voltage 2)
+STO–
15
Grounding PE clamp for hybrid cable line
2
–
32
STO 2 IN: 24 V
(Used for bridging when the
STO function is not required,
see
)
+24V–
16
Grounding PE clamp for hybrid cable line
1
–
33
Cover
–
17
Hybrid cable line 1
–
–
–
–
Table 3.6 Legend to
3.3.1 Connections on the SAB
All required connectors are included with the SAB.
All cabling must comply with national and local regulations
on cable cross-sections and ambient temperature. Use
shielded/armored cables to comply with EMC emission
specifications.
System Description
Operating Instructions
MG75K102
Danfoss A/S © 12/2015 All rights reserved.
19
3
3