7.2.1 Operating LEDs on the Servo Drive
shows the operating LEDs on the servo
drive.
DRIVE STAT
X1
X2
X3
NET STAT
LINK/ACT
DRIVE STAT
X1
X2
NET STAT
LINK/ACT
Advanced
Standard
130BE677.10
Illustration 7.1 Operating LEDs on the Servo Drive
LED
Color
Flash status
Description
DRIVE
STAT
Green On
Servo drive is in state
Operation enabled
.
Flashing
Auxiliary voltage is
applied.
Red
On
Servo drive is in
Fault
or
Fault reaction active
state.
Flashing
DC-link voltage is not
applied.
NET
STAT
Green/
red
Fieldbus dependent
Network status of the
device (see
corresponding fieldbus
standard).
Link/A
CT X1
Green –
Link/activity status of
Hybrid In
(X1)
On
Ethernet link
established.
Flashing
Ethernet link
established and active.
Off
No link.
Link/A
CT X2
Green –
Link/activity status of
Hybrid Out
(X2)
On
Ethernet link
established.
Flashing
Ethernet link
established and active.
Off
No link.
LED
Color
Flash status
Description
Link/A
CT
X3
1)
Green –
Link/activity status of
the Ethernet port (X3).
On
Ethernet link
established.
Flashing
Ethernet link
established and active.
Off
No link.
Table 7.3 Legend to
1) Advanced version only
7.2.2 Operating LEDs on the Servo Access
Box
Aux 1
Aux 2
Safe 1
Safe 2
130BE733.10
Illustration 7.2 Operating LEDs on the SAB
LED
Color
Flash status
Description
Aux 1 Green –
State of the auxiliary
voltage on line 1.
On
Statemachine is in
state
Standby
,
Power
up
, or
Operation
enabled
. Auxiliary
voltage is applied to
the output connectors
on line 1.
Off
Statemachine is in
state
U
AUX
disabled
or
Fault
. Auxiliary voltage
is not applied to line 1.
Operation
VLT
®
Integrated Servo Drive ISD
®
510 System
64
Danfoss A/S © 12/2015 All rights reserved.
MG75K102
7
7