Decentral Solutions
■
Display modes
The LCP control unit has different display modes,
which depend on the mode selected for the
variable frequency drive.
Display mode I:
This display mode is standard after startup
or initialization.
50.0 Hz
FREQUENCY
MOTOR IS RUNNING
Line 2 shows the data value of an operating data
item with unit, and line 1 contains a text that explains
line 2. In the example,
Frequency
has been selected
as readout via parameter 009
Large display readout
.
In normal operation, another variable can be entered
immediately using the [+ / -] keys.
Display mode II:
Switch between Display modes I and II is performed
by briefly pressing the [DISPLAY / STATUS] key.
MOTOR IS RUNNING
50.0 Hz
24.3% 30.2% 13.8A
In this mode, all data values for four operating
data items with any pertaining units are shown,
see table. In the example, the following have been
selected:
Frequency
,
Reference
,
Torque
and
Current
as readout in the first and second line.
Display mode III:
This display mode is called up as long as the [DISPLAY
/ STATUS] key is held down. When the key is released
it switches back to Display mode II, unless the key is
held down for less than approx. 1 sec., in which case
the system always reverts to Display mode I.
50.0 Hz
SETUP
1
MOTOR IS RUNNING
REF% TORQUE CURR A
Here you can read out the parameter names and
units for operating data in the first and second lines.
Line 2 in the display remains unchanged.