Decentral Solutions
All About FCD
300
■
Emission test results according to generic
standards and PDS product standard
The following test results are achieved on a system
consisting of a FCD 300 400 V screened/armoured
control cable, control box with potentiometer,
screened/armoured motor cable, screened/armoured
brake cable as well as LCP with cable.
VLT FCD 300 with class 1A
RFI-filter
Product standard/environment
Basic standard
Complies
EN 50081-2/Industry
EN55011 group 1 class A
Complies
EN 61800-3/First environment
restricted distribution
CISPR 11 group 1 class A
Complies
EN 61800-3/Second environment
unrestricted distribution
CISPR 11 group 2 class A
FCD 303-315
30 ft (10 m) shielded/armoured motor cable
FCD 322-335
15 ft (5 m) shielded/armoured motor cable
1
1
For 30 ft (10 m) cable please contact Danfoss.
NOTE
FCD 300 with class 1A RFI-filter is a product of
the restricted sales distribution class according
to IEC 61800-3. In a domestic environment this
product may cause radio interference in which case the
user may be required to take adequate measures.
■
Immunity test result according to Generic
standards, PDS product standards and
basic standards
In order to document EMC immunity tests have been
made according to following product standards on a
system consisting of a FCD 300, a shielded armoured
control cable with control box and potentiometer,
shielded/armoured motor cable, shielded/armoured
brake cable and LCP with cable.
FCD 300
Product standard/environment
Test results
Complies
EN 61000-6-2 / Industry
See Basic standards test results.
Complies
EN 61800-3 / Second environment
See Basic standards test results.
Used EMC standards
Emission
EN 50081-2:
Generic emission standard part
2: Industrial environment.
IEC/EN 61800-3:
Adjustable speed electrical Power
Drive STystems part 3: EMC product standard
including specific test methods.
EN 55011:
Industrial, scientific and medical
(ISM) radio-frequency equipment. Limits and
methods of measurement.
CISPR 11:
Industrial, scientific and medical
(ISM) radio-frequency equipment. Limits and
methods of measurement.
Immunity
IEC/EN 61000-6-2:
Generic immunity standard
part 2: Industrial environment.
IEC/EN 61800-3:
Adjustable speed electrical Power
Drive Systems part 3: EMC product standard
including specific test methods.
Basic standards
IEC/EN 61000-4-2:
Electrostatic discharge
immunity test.
IEC/EN 61000-4-3:
Radiated, radio-frequency,
electromagnetic field immunity test.
IEC/EN 61000-4-4:
Electrical fast transient/burst
immunity test.
Simulation of fast switching transients like relay contact
bounce, interruption of inductive loads, etc.
MG.90.F2.22 - VLT is a registered Danfoss trademark
185