Frame
Size
A1
A2
A3
A4
A5
B1
B2
B3
B4
C1
C2
C3
C4
Rated
Power
[kW]
200-240V
0.25–1.5
0.25-2.2
3-3.7
0.25-2.2
0.25-3.7
5.5-7.5
11
5.5-7.5
11-15
15-22
30-37
18.5-22
30-37
380-480/500V
0.37-1.5
0.37-4.0
5.5-7.5
0.37-4
0.37-7.5
11-15
18.5-22
11-15
18.5-30
30-45
55-75
37-45
55-75
525-600V
0.75-7.5
0.75-7.5
11-15
18.5-22
11-15
18.5-30
30-45
55-90
37-45
55-90
525-690V
11-22
30-75
IP NEMA
20
Chassis
20
Chassis
21
Type
1
20
Chassis
21
Type
1
55/66 Type
12
55/66 Type
12
21/
55/66
Type
1/Type 12
21/55/66 Type
1/
Type
12
20
Chassis
20
Chassis
21/55/66 Type
1/
Type
12
21/55/66 Type
1/
Type
12
20
Chassis
20
Chassis
Height
Height
of
back
plate
A
200
mm
268
mm
375
mm
268 mm
375
mm
390
mm
420
mm
480
mm
650
mm
399
mm
520
mm
680
mm
770
mm
550
mm
660
mm
Height
with
de-coupling
plate
for
Fieldbus
cables
A
316
mm
374
mm
374 mm
-
-
-
-
-
420
mm
595
mm
630
mm
800
mm
Distance
between
mounting
holes
a
190
mm
257
mm
350
mm
257 mm
350
mm
401
mm
402
mm
454
mm
624
mm
380
mm
495
mm
648
mm
739
mm
521
mm
631
mm
Width
Width
of
back
plate
B
75
mm
90
mm
90
mm
130 mm
130
mm
200
mm
242
mm
242
mm
242
mm
165
mm
230
mm
308
mm
370
mm
308
mm
370
mm
Width
of
back
plate
with
one
C
option
B
130
mm
130
mm
170 mm
170
mm
242
mm
242
mm
242
mm
205
mm
230
mm
308
mm
370
mm
308
mm
370
mm
Width
of
back
plate
with
two
C
options
B
150
mm
150
mm
190 mm
190
mm
242
mm
242
mm
242
mm
225
mm
230
mm
308
mm
370
mm
308
mm
370
mm
Distance
between
mounting
holes
b
60
mm
70
mm
70
mm
110 mm
110
mm
171
mm
215
mm
210
mm
210
mm
140
mm
200
mm
272
mm
334
mm
270
mm
330
mm
Depth
Depth
without
option
A/B
C
207
mm
205
mm
207
mm
205 mm
207
mm
175
mm
195
mm
260
mm
260
mm
249
mm
242
mm
310
mm
335
mm
333
mm
333
mm
With
option
A/B
C
222
mm
220
mm
222
mm
220 mm
222
mm
175
mm
195
mm
260
mm
260
mm
262
mm
242
mm
310
mm
335
mm
333
mm
333
mm
Screw
holes
c
6.0
mm
8.0
mm
8.0
mm
8.0
mm
8.0
mm
8.25
mm
8.25
mm
12
mm
12
mm
8
mm
12.5
mm
12.5
mm
d
ø8
mm
ø11
mm
ø11
mm
ø11 mm
ø11
mm
ø12
mm
ø12
mm
ø19
mm
ø19
mm
12
mm
ø19
mm
ø19
mm
e
ø5
mm
ø5.5
mm
ø5.5
mm
ø5.5 mm
ø5.5
mm
ø6.5
mm
ø6.5
mm
ø9
mm
ø9
mm
6.8
mm
8.5
mm
ø9
mm
ø9
mm
8.5
mm
8.5
mm
f
5
mm
9
mm
9
mm
9
mm
9
mm
6
mm
9
mm
9
mm
9
mm
7.9
mm
15
mm
9.8
mm
9.8
mm
17
mm
17
mm
Max
weight
2.7
kg
4.9
kg
5.3
kg
6.6
kg
7.0
kg
9.7
kg
13.5/14.2
kg
23
kg
27
kg
12
kg
23.5
kg
45
kg
65
kg
35
kg
50
kg
Front
cover
tightening
torque
Plastic
cover
(low
IP)
Click
Click
Click
-
-
Click
Click
Click
Click
Click
Click
2.0
Nm
2.0
Nm
Metal
cover
(IP
55/66)
-
-
-
1.5
Nm
1.5
Nm
2.2
Nm
2.2
Nm
-
-
2.2
Nm
2.2
Nm
2.0
Nm
2.0
Nm
Mechanical Installation - F...
FC 300 Design Guide
MG.33.BD.02 - VLT
®
is a registered Danfoss trademark
119
6
6