0-13 Readout: Linked Set-ups
Array [5]
Range:
Function:
0
*
[0 - 255 ] View a list of all the set-ups linked by means of
0-12 This Set-up Linked to
. The parameter has one
index for each parameter set-up. The parameter
value displayed for each index represents which
set-ups are linked to that parameter set-up.
Index
LCP value
0
{0}
1
{1,2}
2
{1,2}
3
{3}
4
{4}
Table 3.2 Example: Set-up 1 and Set-up 2 are
linked
0-14 Readout: Edit Set-ups / Channel
Range:
Function:
0
*
[-2147483648 -
2147483647 ]
View the setting of
for
each of the four different communication
channels. When the number is displayed in
hex, as it is in the LCP, each number
represents one channel.
Numbers 1-4 represent a set-up number;
‘F’ means factory setting; and ‘A’ means
active set-up. The channels are, from right
to left: LCP, FC-bus, USB, HPFB1-5.
Example: The number AAAAAA21h means
that the FC bus selected Set-up 2 in
, the LCP selected Set-up 1
and all others used the active set-up.
0-15 Readout: actual setup
Range:
Function:
0
*
[0 - 255 ] Makes it possible to read out the active set-up,
also when multi set-up is selected in
.
3.2.3 0-2* LCP Display
Define the variables displayed in the Graphical Local
Control Panel.
NOTE
Please refer to
0-37 Display Text 1
,
0-38 Display Text 2
and
0-39 Display Text 3
for information on how to write display
texts.
0-20 Display Line 1.1 Small
Option:
Function:
Select a variable for display in
line 1, left position.
[0]
*
None
No display value selected.
[9]
Performance Monitor
[15]
Readout: actual setup
[37]
Display Text 1
[38]
Display Text 2
[39]
Display Text 3
[748]
PCD Feed Forward
[953]
Profibus Warning
Word
[1005]
Readout Transmit
Error Counter
[1006]
Readout Receive Error
Counter
[1007]
Readout Bus Off
Counter
[1013]
Warning Parameter
[1230]
Warning Parameter
[1472]
Legacy Alarm Word
[1473]
Legacy Warning
Word
[1474]
Leg. Ext. Status Word
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
Present control word
[1601]
Reference [Unit]
Total reference (sum of digital/
analog/preset/bus/freeze ref./
catch up and slow-down) in
selected unit.
[1602]
Reference %
Total reference (sum of digital/
analog/preset/bus/freeze ref./
catch up and slow-down) in
percent.
[1603]
Status Word
Present status word.
[1605]
Main Actual Value [%] Actual value as a percentage.
[1609]
Custom Readout
[1610]
Power [kW]
Actual power consumed by the
motor in kW.
[1611]
Power [hp]
Actual power consumed by the
motor in HP.
[1612]
Motor Voltage
Voltage supplied to the motor.
[1613]
Frequency
Motor frequency, i.e. the output
frequency from the frequency
converter in Hz
[1614]
Motor Current
Phase current of the motor
measured as effective value.
Parameter Descriptions
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®
is a registered Danfoss trademark
27