2.1.1 The LCD-Display
The LCD-display has back light and a total of 6 alpha-
numeric lines. The display lines show the direction of
rotation (arrow), the chosen Set-up as well as the
programming Set-up. The display is divided into 3 sections.
Top section shows up to 2 measurements in normal
operating status.
The top line in the Middle section shows up to 5
measurements with related unit, regardless of status
(except in the case of alarm/warning).
Bottom section always shows the state of the frequency
converter in Status mode.
Top section
Middle section
Bottom section
Status
43 RPM
1.4 Hz
Auto Remote Running
! Pwr.card temp (W29)
2.9%
5.44 A
25.3kW
1(1)
130BP074.10
!
Illustration 2.2
The Active Set-up (selected as the Active Set-up in
) is shown. When programming another
Set-up than the Active Set-up, the number of the
programmed Set-up appears to the right.
Display contrast adjustment
Press [Status] and [
▲
] for darker display
Press [Status] and [
▼
] for brighter display
Most parameter set-ups can be changed immediately via
the LCP, unless a password has been created via
or via
Indicator lights (LEDs)
If certain threshold values are exceeded, the alarm and/or
warning LED lights up. A status and alarm text appear on
the LCP.
The ON LED is activated when the frequency converter
receives mains voltage or via a DC bus terminal or 24 V
external supply. At the same time, the back light is on.
•
Green LED/On: Control section is working.
•
Yellow LED/Warn.: Indicates a warning.
•
Flashing Red LED/Alarm: Indicates an alarm.
On
Warn.
Alarm
130BP044.10
Illustration 2.3
LCP Keys
The control keys are divided into functions. The keys
below the display and indicator lamps are used for
parameter Set-up, including choice of display indication
during normal operation.
130BP045.10
Status
Quick
Menu
Main
Menu
Alarm
Log
Illustration 2.4
[Status] indicates the status of the frequency converter
and/or the motor. Choose between 3 different readouts by
pressing the [Status] key: 5 line readouts, 4 line readouts
or Smart Logic Control.
Use [Status] for selecting the mode of display or for
changing back to Display mode from either the Quick
Menu mode, the Main Menu mode or Alarm mode. Also
use the [Status] key to toggle single or double read-out
mode.
[Quick Menu] allows quick access to different Quick Menus
such as
•
My Personal Menu
•
Quick Set-up
•
Changes Made
•
Loggings
Use [Quick Menu] for programming the parameters
belonging to the Quick Menu. It is possible to switch
directly between Quick Menu mode and Main Menu mode.
[Main Menu] is used for programming all parameters.
It is possible to switch directly between Main Menu mode
and Quick Menu mode.
Parameter shortcut can be carried out by pressing down
the [Main Menu] key for 3 seconds. The parameter shortcut
allows direct access to any parameter.
How to Programme
VLT
®
AutomationDrive Programmming Guide
12
MG33ME02 - VLT
®