Par.
No.
#
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion
index
Type
32-73 Integral limit filter time
0 ms
2 set-ups
TRUE
-3
Int16
32-74 Position error filter time
0 ms
2 set-ups
TRUE
-3
Int16
32-8* Velocity & Accel.
32-80 Maximum Velocity (Encoder)
1500 RPM
2 set-ups
TRUE
67
Uint32
32-81 Shortest Ramp
1.000 s
2 set-ups
TRUE
-3
Uint32
32-82 Ramp Type
[0] Linear
2 set-ups
TRUE
-
Uint8
32-83 Velocity Resolution
100 N/A
2 set-ups
TRUE
0
Uint32
32-84 Default Velocity
50 N/A
2 set-ups
TRUE
0
Uint32
32-85 Default Acceleration
50 N/A
2 set-ups
TRUE
0
Uint32
32-86 Acc. up for limited jerk
100 ms
2 set-ups
TRUE
-3
Uint32
32-87 Acc. down for limited jerk
0 ms
2 set-ups
TRUE
-3
Uint32
32-88 Dec. up for limited jerk
0 ms
2 set-ups
TRUE
-3
Uint32
32-89 Dec. down for limited jerk
0 ms
2 set-ups
TRUE
-3
Uint32
32-9* Development
32-90 Debug Source
[0] Controlcard
2 set-ups
TRUE
-
Uint8
Table 4.26
Parameter Lists
VLT
®
AutomationDrive Programmming Guide
190
MG33ME02 - VLT
®
is a registered Danfoss trademark
4