4.1.22 32-** MCO Basic Settings
Par.
No.
#
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion
index
Type
32-0* Encoder 2
32-00 Incremental Signal Type
[1] RS422 (5V TTL)
2 set-ups
TRUE
-
Uint8
32-01 Incremental Resolution
1024 N/A
2 set-ups
TRUE
0
Uint32
32-02 Absolute Protocol
[0] None
2 set-ups
TRUE
-
Uint8
32-03 Absolute Resolution
8192 N/A
2 set-ups
TRUE
0
Uint32
32-04 Absolute Encoder Baudrate X55
[4] 9600
All set-ups
FALSE
-
Uint8
32-05 Absolute Encoder Data Length
25 N/A
2 set-ups
TRUE
0
Uint8
32-06 Absolute Encoder Clock Frequency
262.000 kHz
2 set-ups
TRUE
0
Uint32
32-07 Absolute Encoder Clock Generation
[1] On
2 set-ups
TRUE
-
Uint8
32-08 Absolute Encoder Cable Length
0 m
2 set-ups
TRUE
0
Uint16
32-09 Encoder Monitoring
[0] Off
2 set-ups
TRUE
-
Uint8
32-10 Rotational Direction
[1] No action
2 set-ups
TRUE
-
Uint8
32-11 User Unit Denominator
1 N/A
2 set-ups
TRUE
0
Uint32
32-12 User Unit Numerator
1 N/A
2 set-ups
TRUE
0
Uint32
32-13 Enc.2 Control
[0] No soft changing
2 set-ups
TRUE
-
Uint8
32-14 Enc.2 node ID
127 N/A
2 set-ups
TRUE
0
Uint8
32-15 Enc.2 CAN guard
null
2 set-ups
TRUE
-
Uint8
32-3* Encoder 1
32-30 Incremental Signal Type
[1] RS422 (5V TTL)
2 set-ups
TRUE
-
Uint8
32-31 Incremental Resolution
1024 N/A
2 set-ups
TRUE
0
Uint32
32-32 Absolute Protocol
[0] None
2 set-ups
TRUE
-
Uint8
32-33 Absolute Resolution
8192 N/A
2 set-ups
TRUE
0
Uint32
32-35 Absolute Encoder Data Length
25 N/A
2 set-ups
TRUE
0
Uint8
32-36 Absolute Encoder Clock Frequency
262.000 kHz
2 set-ups
TRUE
0
Uint32
32-37 Absolute Encoder Clock Generation
[1] On
2 set-ups
TRUE
-
Uint8
32-38 Absolute Encoder Cable Length
0 m
2 set-ups
TRUE
0
Uint16
32-39 Encoder Monitoring
[0] Off
2 set-ups
TRUE
-
Uint8
32-40 Encoder Termination
[1] On
2 set-ups
TRUE
-
Uint8
32-43 Enc.1 Control
[0] No soft changing
2 set-ups
TRUE
-
Uint8
32-44 Enc.1 node ID
127 N/A
2 set-ups
TRUE
0
Uint8
32-45 Enc.1 CAN guard
null
2 set-ups
TRUE
-
Uint8
32-5* Feedback Source
32-50 Source Slave
[2] Encoder 2
2 set-ups
TRUE
-
Uint8
32-51 MCO 302 Last Will
[1] Trip
2 set-ups
TRUE
-
Uint8
32-52 Source Master
[1] Encoder 1 X56
2 set-ups
TRUE
-
Uint8
32-6* PID Controller
32-60 Proportional factor
30 N/A
2 set-ups
TRUE
0
Uint32
32-61 Derivative factor
0 N/A
2 set-ups
TRUE
0
Uint32
32-62 Integral factor
0 N/A
2 set-ups
TRUE
0
Uint32
32-63 Limit Value for Integral Sum
1000 N/A
2 set-ups
TRUE
0
Uint16
32-64 PID Bandwidth
1000 N/A
2 set-ups
TRUE
0
Uint16
32-65 Velocity Feed-Forward
0 N/A
2 set-ups
TRUE
0
Uint32
32-66 Acceleration Feed-Forward
0 N/A
2 set-ups
TRUE
0
Uint32
32-67 Max. Tolerated Position Error
20000 N/A
2 set-ups
TRUE
0
Uint32
32-68 Reverse Behavior for Slave
[0] Reversing allowed
2 set-ups
TRUE
-
Uint8
32-69 Sampling Time for PID Control
1 ms
2 set-ups
TRUE
-3
Uint16
32-70 Scan Time for Profile Generator
1 ms
2 set-ups
TRUE
-3
Uint8
32-71 Size of the Control Window (Activation)
0 N/A
2 set-ups
TRUE
0
Uint32
32-72 Size of the Control Window (Deactiv.)
0 N/A
2 set-ups
TRUE
0
Uint32
Parameter Lists
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®
is a registered Danfoss trademark
189