
Pa
r. No.
#
Para
mete
r descripti
on
Def
ault value
4-
se
t-
up
Cha
nge
duri
ng
op
era
-
tio
n
Conve
r-
sion inde
x
Type
22-0
*
Mi
sce
llaneous
22-
00
Exte
rnal Interlock
D
el
ay
0 s
All se
t-
up
s
TRU
E
0
Ui
nt16
22-2
*
No-Flow D
et
ec
ti
o
n
22-
20
Lo
w
Po
we
r Auto
Se
t-
up
[0
] O
ff
All se
t-
up
s
FA
LS
E
-
U
in
t8
22-
21
Lo
w P
owe
r
Dete
ctio
n
[0]
Di
sab
led
All se
t-
up
s
TRU
E
-
Ui
nt8
22-
22
Lo
w Sp
ee
d
Dete
ctio
n
[0]
Disa
ble
d
All
se
t-u
ps
TRUE
-
Uint
8
22-
23
No-Flow F
uncti
on
[0
] O
ff
All se
t-
up
s
TRU
E
-
Ui
nt8
22-
24
No
-F
lo
w Del
ay
10 s
Al
l set-
up
s
TR
U
E
0
Ui
nt16
22-
26
Dry Pu
m
p Function
[0
] O
ff
All se
t-
up
s
TRU
E
-
Ui
nt8
22-
27
Dry P
ump
De
lay
10 s
Al
l set-
up
s
TR
U
E
0
Ui
nt16
22-
28
No
-F
lo
w Lo
w Spe
ed
[R
PM
]
SR
All se
t-
up
s
TRU
E
67
Ui
nt16
22-
29
No
-F
lo
w Lo
w Spe
ed
[Hz]
SR
All se
t-
up
s
TRU
E
-1
Ui
nt16
2
2
-3*
No-
Flow Pow
er
Tu
ning
22-
30
No-Flow Pow
er
0.
00 kW
All se
t-
up
s
TRU
E
1
U
in
t3
2
22-
31
Power C
orrection Factor
100
%
All se
t-
up
s
TRU
E
0
Ui
nt16
22-
32
Lo
w Sp
ee
d
[R
PM
]
SR
All se
t-
up
s
TRU
E
67
U
in
t1
6
22-
33
Low Spe
ed
[Hz]
SR
All se
t-
up
s
TRU
E
-1
Ui
nt16
22-
34
Lo
w
Sp
ee
d P
owe
r [kW]
SR
All se
t-
up
s
TRU
E
1
U
in
t3
2
22-
35
Lo
w
Sp
ee
d P
owe
r [HP
]
SR
All se
t-
up
s
TRU
E
-2
Ui
nt32
22-
36
Hi
gh
Sp
ee
d [R
PM
]
SR
All se
t-
up
s
TRU
E
67
U
in
t1
6
22-
37
H
igh Spe
ed [
H
z]
SR
All se
t-
up
s
TRU
E
-1
Ui
nt16
22-
38
Hi
gh
Sp
ee
d P
owe
r [kW]
SR
All se
t-
up
s
TRU
E
1
U
in
t3
2
22-
39
H
igh Spe
ed Pow
er [
H
P]
SR
All se
t-
up
s
TRU
E
-2
Ui
nt32
22-4
*
Sle
ep
Mode
22-
40
Mi
ni
mu
m Ru
n T
im
e
60 s
All se
t-
up
s
TRU
E
0
Ui
nt16
22-
41
M
inim
um
Sle
ep
Time
30 s
Al
l set-
up
s
TR
U
E
0
Ui
nt16
22-
42
Wak
e-u
p S
pee
d [
R
PM
]
SR
All se
t-
up
s
TRU
E
67
Ui
nt16
22-
43
Wake
-u
p S
pe
ed
[Hz
]
SR
All se
t-
up
s
TRU
E
-1
U
in
t1
6
22-
44
Wak
e-u
p R
ef.
/FB Dif
fere
nce
10 %
All se
t-
up
s
TRU
E
0
In
t8
22-
45
Se
tpo
int Bo
os
t
0 %
Al
l se
t-u
ps
TRUE
0
In
t8
22-
46
M
ax
imum Boost Tim
e
60 s
All se
t-
up
s
TRU
E
0
Ui
nt16
22-5
*
En
d of
Cu
rv
e
22-
50
En
d of
Curve
Functi
on
[0
] O
ff
All se
t-
up
s
TRU
E
-
Ui
nt8
22-
51
En
d of
Curve
De
lay
10 s
All se
t-
up
s
TRU
E
0
Ui
nt16
22-6
*
Broke
n
B
elt
D
et
ec
ti
o
n
22-
60
Broke
n Bel
t Functi
on
[0
] O
ff
All se
t-
up
s
TRU
E
-
U
in
t8
22-
61
Broken Be
lt
Torq
ue
10 %
All se
t-
up
s
TRU
E
0
Ui
nt8
22-
62
Broken Be
lt
D
el
ay
10 s
All se
t-
up
s
TRU
E
0
Ui
nt16
22-7
*
Sh
ort
Cyc
le P
ro
te
ction
22-
75
Short
Cycle
Prote
ctio
n
[0]
Di
sab
led
All se
t-
up
s
TRU
E
-
U
in
t8
22-
76
Int
erva
l be
twe
en St
arts
st
art_to_
start_mi
n_o
n_
time
(P
227
7)
All se
t-
up
s
TRU
E
0
Ui
nt16
22-
77
M
inim
um
R
un Ti
me
0 s
Al
l set-
up
s
TR
U
E
0
Ui
nt16
3.1.19
Applicat
ion Funct
ions 22
-**
3 Parameter Lists
VLT
®
AQUA Drive Programming Guide
260
MG.20.O4.02 - VLT
®
is a registered Danfoss trademark
3