FLR3-1500 and FLD3-2000 Handheld Controller
41
The following prompt is shown for both
MANUAL
and
AUTOMATIC
dimming selections:
LCD Screen
Action/Information Shown
INTENSITY XX}{*
ENTER TO SET
XX – Current intensity (01-63)
Max Intensity – 63
Press the
Up
and
Down Arrow
keys to modify the display’s
current intensity.
Note:
The DM-100 must be communicating with the display.
Press
ENTER
to accept this intensity.
When manual dimming mode is selected, this is the display’s
new intensity.
When automatic dimming mode is selected, the display
illuminates in full-bright mode, which is the maximum intensity
level.
When
BLANK SIGN
is selected, the following prompt appears:
LCD Screen
Action/Information Shown
BLANK THE SIGN?
<ENT> YES
BLANK THE SIGN?
<CLR> NO
Press
ENTER
to blank the sign.
Press
CLEAR
to leave the sign on.
When in Blank Mode, the digits on all of the displays will turn
off and only the decimal will be lit.
RESTART SIGN?
<ENT> YES
RESTART SIGN?
<CLR> NO
To turn the sign back on, first press the
DIMMING
key, and then
press
ENTER
.
To leave the sign blank, press
CLEAR
.
Update the Display
After connecting to the display with the handheld controller, press
UPDATE DISPLAY
to
send prices to the display. The DM-100 shows a response or an error code.