FLR3-1500 and FLD3-2000 Handheld Controller
39
LCD Screen
Action/Information Shown
DIAGNOSTICS
POS PORT MONITOR
USE POS DEFALTS?
1-YES 2-NO
INCOMING DATA...
Press
ENTER
to begin the
PoS Port Monitor
.
Press
1
to use the PoS default settings, or press
2
to change these
settings.
Note:
If 2 is pressed, see below for settings to select.
The LCD will display INCOMING DATA...(data received from the
PoS)
Press
ENTER
to exit.
SELECT BAUD RATE
9600 }{
SELECT STOP BITS
1 {
Change the Baud Rate and Stop Bits as needed for the PoS
system in use. Consult the PoS system manual for specifics.
Press the
Up
and
Down Arrow
keys to select the appropriate Baud
Rate, and then press
ENTER
. Default Baud Rate = 9600
Press the
Up
and
Down Arrow
keys to select the appropriate Stop
Bits, and then press
ENTER
. Default Stop Bits = 1
DIAGNOSTICS
COM PORT TESTS
SELECT TEST }
RS232 COM0
SELECT TEST {}
RS232 COM0]COM1
SELECT TEST {}
RS232 COM1
SELECT TEST {
CURRENT LOOP
Press
ENTER
to test the operation of the DM-100 COM ports and/
or cables. These tests are useful for determining if the ports
themselves are operational and if cables are good.
Press the
Up
and
Down Arrow
keys to select the appropriate test,
and then press
ENTER
.
• RS232 COM0 – Checks for a “loopback” jumper on pins 2 & 3
of the top-left connector (FAIL if a loopback is not detected).
• RS232 COM0->COM1 – Checks for transmit and receive
connections between the top-left and top-right connectors
(FAIL if the ports are not connected together).
• RS232 COM1 – Checks for a “loopback” jumper on pins 2 & 3
of the top-right connector (FAIL if a loopback is not detected).
• CURRENT LOOP – Checks for “loopback” jumpers on the left
connector between pins 6 & 8 and 5 & 9 (FAIL if jumpers not
detected).
Press
ENTER
to exit.
DIAGNOSTICS
POS STATUS
This menu is only used for internal Daktronics testing purposes.