Cash/Credit Display Installation
12
Use
Grounding
Stud
SERIAL #
LABEL B
LABEL A
LABEL C
Figure 24:
Internal Component Locations
Grounding
Cash/Credit displays do not require a local earth ground electrode�
Power Installation
Install Daktronics Cash/Credit displays using a
two-wire plus ground circuit. The ground from the
circuit must be connected to the grounding stud
within each Cash/Credit display. Do not connect
neutral to ground at the disconnect or at the
display, this would violate electrical codes and
void the warranty. Use a disconnect so that all
ungrounded conductors can be disconnected.
To connect power to the display, follow these steps:
1�
Route power cable into the display through one of the knockouts on the display’s
backsheet.
2�
Use wire nuts or other appropriate hardware to connect power wires - hot (black)
and neutral (white) - to the power supply harness or pigtail. Refer to
3�
Connect supply power ground wire to the grounding stud. Refer to
Note:
Verify the power supply ground wire is connected to the grounding stud.
Connect to the Fuelight Driver
Connect the 8-position Mate-N-Lok plug from the cash/credit module harness to jack J18
on a Fuelight driver. Refer to
Figure 26:
Cash/Credit Display
Connection to Driver
Figure 25:
Power Connection