Specifications
SiBE37-701
46
Specifications
Ceiling Suspended Unit
1-1 TECHNICAL SPECIFICATIONS
FXHQ32MAVE
FXHQ63MAVE
FXHQ100MAVE
Nominal
Capacity
Cooling
kW
3.60
7.10
11.20
Heating
kW
4.00
8.00
12.50
Power input
(Nominal)
Cooling
kW
0.111
0.115
0.135
Heating
kW
0.111
0.115
0.135
Casing
Colour
White (10Y9/0.5)
Dimensions
Unit
Height
mm
195
195
195
Width
mm
960
1,160
1,400
Depth
mm
680
680
680
Weight
Unit
kg
24
28
33
Heat
Exchanger
Dimensions Nr of Rows
2
3
3
Fin Pitch
mm
1.75
1.75
1.75
Face Area
m²
0.182
0.233
0.293
Nr of Stages
12
12
12
Fan
Type
Sirocco fan
Quantity
1
1
1
Air Flow
Rate
Cooling
High
m³/min
12.00
17.50
25.00
Low
m³/min
10.00
14.00
19.50
Fan
Motor
Quantity
1
1
1
Model
3D12K1AA1
4D12K1AA1
3D12K2AA1
Output
(high)
W
62
62
130
Drive
Direct drive
Refrigerant
Name
R-410A
Cooling
Sound
Pressure
High
dBA
36.0
39.0
45.0
Low
dBA
31.0
34.0
37.0
Piping
connections
Liquid
(OD)
Type
Flare connection
Diameter
mm
6.4
9.5
9.5
Gas
Type
Flare connection
Diameter
mm
12.7
15.9
15.9
Drain
Diameter
mm
26
26
26
Heat Insulation
Glass wool
Air Filter
Resin net with mold resistance
Refrigerant control
Electronic expansion valve
Temperature control
Microprocessor thermostat for cooling and heating
Safety devices
PC board fuse
Fan motor thermal protector
Standard
Accessories
Standard Accessories
Installation and operation manual
Drain hose
Paper pattern for installation
Clamp metal
Insulation for fitting
Clamps
Washer
Notes
Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB,
equivalent refrigerant piping : 7.5m (horizontal)
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB,
equivalent refrigerant piping : 7.5m (horizontal)
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Summary of Contents for VRV III REYQ8PY1B
Page 1: ...REYQ8 48PY1B R 410A Heat Recovery 50Hz SiBE37 701...
Page 111: ...Refrigerant Flow for Each Operation Mode SiBE37 701 100 Refrigerant Circuit...
Page 252: ...SiBE37 701 Troubleshooting by Remote Controller Troubleshooting 241...
Page 396: ...SiBE37 701 Piping Diagrams Appendix 385 REYQ14P 16P 3D058153B S2NPL S1NPH...
Page 397: ...Piping Diagrams SiBE37 701 386 Appendix REMQ8P 3D057743...
Page 398: ...SiBE37 701 Piping Diagrams Appendix 387 REMQ10P 12P 3D057742...
Page 399: ...Piping Diagrams SiBE37 701 388 Appendix REMQ14P 16P 3D057741...
Page 400: ...SiBE37 701 Piping Diagrams Appendix 389 1 2 Indoor Unit FXFQ P...
Page 405: ...Piping Diagrams SiBE37 701 394 Appendix 1 3 BS Unit 4D057985A...
Page 415: ...Wiring Diagrams for Reference SiBE37 701 404 Appendix FXZQ20M 25M 32M 40M 50MV1...
Page 416: ...SiBE37 701 Wiring Diagrams for Reference Appendix 405 FXCQ20M 25M 32M 63MV3...
Page 417: ...Wiring Diagrams for Reference SiBE37 701 406 Appendix FXCQ40M 50M 80M 125MV3...
Page 420: ...SiBE37 701 Wiring Diagrams for Reference Appendix 409 FXDQ20M 25MV3...
Page 421: ...Wiring Diagrams for Reference SiBE37 701 410 Appendix FXSQ20M 25M 32M 40M 50M 63MV3...
Page 422: ...SiBE37 701 Wiring Diagrams for Reference Appendix 411 FXSQ80M 100M 125MV3...
Page 447: ...Example of connection SiBE37 701 436 Appendix...
Page 453: ...Method of Checking the Inverter s Power Transistors and Diode Modules SiBE37 701 442 Appendix...
Page 467: ...SiBE37 701 iv Index...