![background image](http://html1.mh-extra.com/html/daikin/fhq100buv3b/fhq100buv3b_service-manual_2459262022.webp)
General Outline
ESIE05-04
1–4
Part 1 – System Outline
3
1
1
4
5
1.2
FCQ35, 50, 60, 71B
Outlook and
dimensions
The illustration below shows the outlook and the dimensions of the unit (mm).
REQUI
RE
D INST
AL
L
A
T
IO
N
SPACE
WHEN T
HE DISCHARGE G
RIL
L
IS CL
O
S
E
D
,
THE REQ
UI
RED SPACE I
S
2
0
0
m
m
O
R
M
O
RE.
o
r
m
o
re
o
r
m
o
re
o
r
m
o
re
o
r
m
o
re
B
ran
ch duct
con
nection
P
re
pare
d hol
e
P
repar
ed ho
le
B
ran
ch duct
con
nection
(C
ei
ling op
eni
ng)
(S
uspe
nsi
on po
si
ti
on)
(Cei
ling o
pening)
(Suspe
nsion p
osi
tion)
or
less
P
rep
ared
hol
e
B
ranch d
u
ct
conne
ction
Installation space
H
angi
n
g
bol
t
Ad
justable
VIEW A
VIEW C
P
re
pare
d hol
e
F
o
r fr
esh air
intake
kit
con
necti
on (di
re
ct
insta
lla
tion type
)
see n
o
te 3
or mo
re
VIEW
B
VIEW
D
NOT
E
S
:
1.
Loc
ati
on
of
the
na
me
pl
ate
s:
- Un
it bo
dy:
on
the
bell
m
o
u
th
at t
he in
side
of
the
suct
io
n g
rill.
- De
cor
a
tion
pa
ne
l:
on
the
pa
nel
fr
a
m
e
at t
he
in
side
of
the
suct
ion g
rill.
2.
When
inst
alling
an
opt
iona
l acce
ssor
y
, r
e
fe
r to
th
e ins
tallat
ion d
ra
wings
.
- F
o
r the
fr
esh
air in
take
kit .
....
an
inspe
ction
po
rt
is
ne
cessa
ry
- F
o
r the
hig
h e
fficien
cy filte
r .
.... a
n
in
spe
ction
po
rt is
nece
ssar
y
- F
o
r the
br
anc
h d
u
ct c
ham
be
r ..
.. a
n
i
n
s
pect
ion p
o
rt
i
s
n
e
ce
ssar
y
3.
In
case
of
using
a w
ir
e
le
ss r
e
m
o
te c
ontr
o
lle
r,
th
is po
sition
will be
a
signa
l
re
ceive
r. Refe
r to th
e dr
awing
o
f the wir
eless r
e
mo
te co
ntr
oller
fo
r mo
re
d
e
ta
ils
.
4.
Whe
n
th
e co
nd
it
ions
exce
ed
30°
C an
d RH
80%
in
the
ceilin
g o
r fr
esh
air
is
in
d
u
cte
d
in
to the
ce
ili
n
g
, an
ad
di
ti
o
nal
in
su
la
ti
on
is
re
qui
red (p
ol
yet
hyl
e
n
e
foa
m,
thi
ck
ness
10
mm
or
mo
re)
.
Summary of Contents for FHQ100BUV3B
Page 1: ...Service Manual ESIE05 04 R 410A Sky Air Indoor...
Page 2: ......
Page 20: ...ESIE05 04 1 2 Part 1 System Outline 3 1 1 5...
Page 62: ...General Outline ESIE05 04 1 44 Part 1 System Outline 3 1 1 4 5...
Page 78: ...ESIE05 04 1 60 Part 1 System Outline...
Page 112: ...Wiring Diagrams ESIE05 04 1 94 Part 1 System Outline 3 1 1 4 5...
Page 140: ...ESIE05 04 2 2 Part 2 Functional Description 3 1 2 5...
Page 164: ...ESIE05 04 3 2 Part 3 Troubleshooting 3 1 3 5...
Page 206: ...Error Codes ESIE05 04 3 44 Part 3 Troubleshooting 3 1 3 4 5...
Page 224: ...Additional Checks for Troubleshooting ESIE05 04 3 62 Part 3 Troubleshooting 3 1 3 4 5...
Page 226: ...ESIE05 04 4 2 Part 4 Commissioning and Test Run 3 1 4 5...
Page 252: ...ESIE05 04 5 2 Part 5 Disassembly and Maintenance 3 1 5...
Page 384: ...Disassembly and Maintenance ESIE05 04 5 134 Part 5 Disassembly and Maintenance 3 1 5 5...
Page 390: ...ESIE05 04 vi Index 3 1 4 5 W Wiring diagrams Indoor units k 1 61...