Main Functions
Si18-201
86
Main Functions
Clean the Front
Grille.
"
You may wipe it with a soft cloth soaked in water.
"
Only neutral detergent may be used.
"
You may wash the grille with water. After washing, dry it with cloth, then dry it up in the
shade.
Attach the Front
Grille.
"
Set the 3 keys of the front grille into the slots and push them in all the way.
"
Supporting the front grille with one hand, fit the lock by sliding up the knob with the other
hand.
"
Close the front grille slowly in this state. (Push the grille at the 3 points, two at both sides and
in the middle).
Caution
"
When removing or attaching the front grille, use a robust and stable stool and watch your
steps carefully.
"
When removing or attaching the front grille, support the grille securely with a hand to prevent
it from falling.
"
For cleaning, do not use water hotter than 40ºC, benzine, gasoline, thinner, nor other volatile
oils, polishing compound, scrubbing brushes nor other hard stuff.
"
After cleaning, make sure that the front grille is securely fixed.
1.1.11
Filter Cleaning Indicator
For FTK, FTX50/
60 H Series Only
"
The filter check indicator located at the center of the unit will indicate the time for
cleaning the air filters.
The indicator will indicate an appropriate cleaning time depending on the environment (dusty
place or not). This will prevent you from forgetting filter cleaning and also prevent performance
drop that might be caused by using clogged filters and wasteful use of electricity by
approximately 8%.
Contents of
Indication
"
Sensed by the operation hours and the fan motor voltage
Indicates the earlier one of the above 1) or 2).
*This indicator utilizes the characteristic that the fan motor voltage drops as the crossflow fan
gets clogged; it does not detects the amount of filter clogging.
Note:
"
When the power supply is reset, the accumulated operation hour is also reset.
"
After cleaning and mounting the filters, press the reset button located inside the panel of the
unit.
Summary of Contents for BPMK928B42
Page 9: ...Si18 201 viii Table of Contents ...
Page 71: ...Specifications Si18 201 58 Specifications ...
Page 206: ...Si18 201 Remote Controller Operations 193 1 1 2 FVX25 35KZ ...
Page 207: ...Remote Controller Si18 201 194 Operations 1 1 3 FTXD25 35KZ ...
Page 208: ...Si18 201 Remote Controller Operations 195 1 1 4 FTK FTX50 60H ...
Page 209: ...Remote Controller Si18 201 196 Operations 1 1 5 FTKD FTXD50 60 71J ...
Page 214: ...Si18 201 Remote Controller Operations 201 ...
Page 216: ...Si18 201 Remote Controller Operations 203 ...
Page 217: ...Remote Controller Si18 201 204 Operations ...
Page 237: ...Method of Field Set Si18 201 224 Operating Test ...
Page 262: ...Si18 201 Troubleshooting SkyAir Indoor Unit Service Diagnosis 249 ...
Page 393: ...Wiring Diagrams Si18 201 380 Appendix FHYC35 50 60 71KVE9 3D005668C ...
Page 394: ...Si18 201 Wiring Diagrams Appendix 381 FHYC35 50 60 71KV1C9 ...
Page 395: ...Wiring Diagrams Si18 201 382 Appendix FDYM60 03FAV1 FDYM60 03FAVAL C 3D019816D OPTION ...
Page 396: ...Si18 201 Wiring Diagrams Appendix 383 FDYM60 03FAV1C ...