User’s Manual
4
Type
Parameter
Description
Power Supply
Main Power
Type A: 110–240 VAC, 50/60 Hz
Conformity
EN 50131-6
Max.
Consumption
800 mA@230 VAC; 1300 mA@ 115 VAC
Max. Output
Voltage
2.76 [email protected] VDC
Max. Current
Available
2.76 A
Max. Ripple
Max. 30mV
Power
Consumption
Max. 40 W
Max. Output
Voltage
12 V; 1A
Mains fuse (non
-replaceable)
RT21: 5 A
Battery
Battery
Capacity
1 x 12 V/7.2 Ah
Battery Flame
Class
UL94 FV0
Standards
IEC 60896 Part 21 - VRLA methods of testing
IEC 60896 Part 22 - VRLA requirements
Eurobat 3-5 years standard commercial for FG FGH
FGC and 10-12 years long life for FGHL
UL Recognized
Battery Low
Battery
Threshold
11.8 VDC
Battery Restore
Threshold
12.3 VDC
Battery Standby
Up to 12 hrs
440 mA as max load in order to have autonomy of 12 h.
Release Voltage
<
10.8 V
Failure
Signaling
<
5 V
Overcharge
Signaling
14.5 V
Battery
Recharge Time
80% approx. 48 h
ARC Signaling
ATS Category
SP2 (PSTN or GSM)
DP1 (PSTN + GSM)
Acknowledgem
ent Operation
Pass through
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Page 137: ...User s Manual...