User’s Manual
32
Alarm Input Module
8 alarm inputs and 2 alarm outputs are supported with alarm input modules. The alarm input
module with Dip switch address 1 receives alarm input signals from wired zones of 9–16, and
connects to alarm output devices of 3–4. Other alarm input modules are connected by analogy till
the module addressed 8, which receives alarm input signals from wired zones of 65–72, and
connects to alarm output devices of 17–18.
Alarm Output Module
8 alarm outputs are supported with alarm output modules. The alarm output module with Dip
switch address 1 connects to alarm output devices of 19–26. Other alarm output modules are
connected by analogy till the module addressed 8, which connects to alarm output devices of 75–82.
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...