Table 2-1 Function
No.
Name
Function
1
DIP switch
Restores to the factory settings.
2
Network port
Connects to Ethernet port.
3
LINK indicator
Network indicator.
4
ACTIVE indicator
Network indicator.
5
Z1–Z8
Zone 1–Zone 8.
G
Ground.
6
+12V
Auxiliary power output 12 VDC with 1000 mA.
G
Ground.
7
ST
Tamper port, and generally used as siren tamper.
G
Ground.
SIREN
Connects to siren.
8
NC, COM, NO
Relay port. The maximum touch point load is 0.5 A, 125 VAC/1
A, 30 VDC.
9
OUT_1, OUT_2
Alarm output driven by MOS.
G
Ground.
10
VBAT
Positive pole and negative pole of battery. The negative pole
must receive ground connection.
G
Ground.
11
TIP_O, RING_O
Telephone connection port.
12
TIP_IN, RING_IN
Telephone line port.
13
OUT_1 indicator
ON: OUT_1 is open.
OFF: OUT_1 is closed.
14
OUT_2 indicator
ON: OUT_2 is open.
OFF: OUT_2 is closed.
15
BUS2_TX indicator
Data transmitting indicator of the second group of RS-485
ports.
ON: Transmitting is in process.
16
BUS2_RX indicator
Data receiving indicator of the second group of RS-485 ports.
ON: Date receiving is in process.
17
BUS1_TX indicator
Data transmitting indicator of the first group of RS-485 ports.
ON: Transmitting is in process.
18
BUS1_RX indicator
Data receiving indicator of the first group of RS-485 ports.
ON: Date receiving is in process.
19
A2, B2
Connects to RS-485 expansion module.
20
+12V
Auxiliary power output 12 VDC supplies power to the external
devices such as detectors.
G
Ground.
21
A1, B1
RS-485 port that connects to keypad (maximum 8 Keypads).
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Page 137: ...User s Manual...