User’s Manual
48
Submenu
Setting
ZONE1/ZONE2
Select the zones that you want to combine the alarm linkage.
To select the zone number, enter the number and press
to confirm the
input. You can also press
and
to adjust the number.
●
The
IN AND ZONES
can consist of any combination of wired or wireless
zones and a single zone can also be placed in
AND
by itself. However, it is
suggested not to program zones in
AND
which are of the delayed,
robbery, or panic type as the
AND
result might not guarantee a sufficient
level of security.
●
Setting a zone in
AND
by itself means that a double alarm confirmation
will be obtained for the alarm to activate. This option is very useful for
placing a filter on the first alarm from a zone at a high risk of a
FALSE
ALARM
.
IN SEQUENCE
Establish whether the alarm confirmation between the two zones should take
into account the first and second sequence.
●
YES
: When the alarm is triggered in
ZONE1
, the alarm in
ZONE2
must be
triggered afterwards.
●
NO
: The controller will not take the sequence into account.
TRIGGERS
Establishes the maximum number of alarms that the same zone triggering the
alarm. In practice, a filter is enabled, from a minimum value of 02 (two alarms)
that takes into account the alarms permitted to the zone before triggering the
alarm. The maximum value that can be set is 15.
Using the
TRIGGERS
parameter with the criterion could have a negative
effectiveness and promptness of the installed alarm system.
AND TIME
●
Set the time within which the alarm from the zone 2 must be triggered
after the alarm of zone 1 starts.
●
If the zone 2 opens in this time window, the alarm is confirmed; otherwise,
after this time period, the timer is reset to zero and the first alarm is reset.
The time can be programmed in minutes and seconds.
●
Press
to finish programming of the zone 1 pair in
AND
.
Step 5
Press
to return to the
IN AND ZONES
menu.
Then you can continue with programming other in and zones, or press
to return to the
IN AND ZONES
menu from where you can press
and
to move to the next menu
or press
to exit from the installer menu.
7.9 Outputs
7.9.1 Entering Output Menu
Step 1
After entering the installer menu, press
and
to scroll up and down until you reach
the
OUTPIUTS
menu.
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Page 137: ...User s Manual...