User’s Manual
56
Figure 7-10 Areas
Step 2
Press
to enter the programming mode.
Step 3
Press
and
to select the
AREAS
that you want to configure, and then press
.
By pressing
+ 2, you can enter the
EDITING
mode for changing the description of
areas.
Step 4
Configure the parameters.
Press
and
to alter the options. Press
to confirm the setting and move to the
next submenu.
The two numeric fields 000.00 represent minutes and seconds.
Table 7-11 Areas settings
Submenu
Setting
ENREY D1
Set the entry delay 1 and entry delay 2.
During the delayed period, the alarms are not reported. The valid entry
delay time range is from 30 s to 999 min and 59 s.
EN certificates will not be met if the entry delay time exceeds 45.
ENTRY D2
EXIT DELAY
Set the exit delay time.
The alarm is not valid when it is triggered during exit delay time. When
this value is set to 0, there will be no exit delay time and the arming is
operated directly.
BUZ DU
Set the buzzer alarm duration for each area (minutes/seconds).
BUZ DELAY
Set the buzzer alarm delay duration for each area (minutes/seconds).
IN AND AREA
The area undergoing programming can be programmed to follow
other
AREAS
in
AND
mode.
If the area is in
AND
, it means that the programmed area can no longer
be armed or disarmed through a direct code or remote control.
For example, the protection of staircases shared by two apartments,
which arm when both areas of the two apartments are armed and
disarmed when one of the two systems disarm.
TIMER1/TIMER2/
TIMER3/TIMER4
Provides 4 timers that can be used to control the arming or disarming
of the area.
Press
and
or directly press the value +
to alter the timer
to be set. After making the selection, press
to move to the next
field, and after setting the fourth timer, press
to move to the
AREAS
menu. Select another area or press
to exit the
AREAS
menu.
client ID
The
client ID
is different for each area and represents the identification
used by PSTN. The alarm event links multiple areas and each area
respectively links PSTN transmission.
Step 5
Press
to return to the
AREAS
menu.
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Page 137: ...User s Manual...