7.11 System Functions
Step 1
After entering the installer menu, press
and
to scroll up and down until you reach
the
SYSTEM FUNCTIONS
menu.
Figure 7-11 System functions
Step 2
Press
to enter the programming mode.
Step 3
Configure the parameters.
Press
and
to alter the options. Press
to confirm the setting and move to the
next submenu.
The two numeric fields 000.00 represent minutes and seconds.
Table 7-12 System functions settings
Submenu
Setting
MAX AL CYCLE
Maximum of alarm cycles.
Set the maximum number of alarms that the controller can
generate during an arming cycle. This count is the total of the
maximum number of alarm cycles for all the controller zones. 000
represents that there is no limit.
SYS AL CYCLE
Max system alarm cycles.
Set the maximum number of alarms generated during one alarm
cycle by the controller tamper, siren tamper, module tamper, bus
alarm (if enabled), wireless alarm (if enabled), and supervision
alarm (if enabled). 000 represents that there is no limit.
●
During an arming or disarming period, for events from the
same source (intrusion, bandit, anti-demolition, failure), the
log should be kept at most 10.
●
Then disarm or re-arm the system, the same source log can
save up to 10.
Value is less than 3 exceed from EN50131-3.
PANEL TAMPER AREAS
Set which area(s) the alarm generated by the controller tamper
should be linked. If no area is associated, no controller tamper
alarm will be activated. The control panel tamper can be
assigned to multiple areas.
SIREN TAMPER AREAS
Set which area(s) the alarm generated by the siren tamper (ST)
should be linked.
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Page 137: ...User s Manual...