User’s Manual
12
No.
Name
Function
22
DC_IN
Receives 14.5 VDC power supply.
G
Ground.
23
Case tamper port
The alarm is activated when the case is opened.
24
2G module
Connects to 2G module
25
Charge indicator
ON: Battery is charging.
26
Low power indicator
ON: Battery low power.
If power supplies normally, the indicator will not be ON in case
of low battery.
27
PSTN
Connects to PSTN module.
28
4G module
Connects to 4G module.
29
Power indicator
ON: Power supply is in normal status.
2.3.3 DIP Switch
There are eight DIP switches on the controller with different functions.
Figure 2-5 DIP switch
2.3.3.1 Function
Table 2-2 Function
No.
Name
Function
1
DIP 1
Reserved functions that might be developed in the future.
2
DIP 2
3
DIP 3
ON represents Italian language, OFF represents English.
4
DIP 4
Enables whether to report the siren tamper event and case tamper
event.
●
ON represents
NOT TO REPORT
.
●
OFF (default setting) represents
REPORT ENABLED
.