Figure 7-5 Power supplies
Step 2
Press
to enter the programming mode.
Step 3
Select which areas the battery alarm event must (such as main power loss, battery low
voltage or missing) be sent to.
Step 4
Press
to return to the
POWER SUPPLIES
menu.
Then you can press
and
to move to the next menu or press
to exit from the
installer menu.
7.6 Wired Zones
Step 1
After entering the installer menu, press
and
to scroll up and down until you reach
the
WIRED ZONES
menu.
Figure 7-6 Wired zones
Step 2
Press
to enter the programming mode.
By pressing
+ 2, you can enter the
EDITING
mode for changing the description of
wired zone.
Step 3
Press
and
to select the wired zone that you want to configure, and then press
.
Step 4
Configure the parameters for the selected wired zone.
Table 7-3 Wired zone setting
Submenu
Setting
STATE
●
ACTIVE
: This wired zone is fully operational.
●
ISOLATE
: This wired zone is programmed but permanently bypassed
from the system.
●
TEST
: This wired zone is operational but does not generate alarms.
●
OFF
: This wired zone is not used.
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Page 137: ...User s Manual...