User’s Manual
46
Submenu
Setting
OUTPUT LINK
Each individual wired zone can be programmed to command a
LINK
type
output every time it is opened. The corresponding
LINK
output must be then
programmed in the
OUTPUT
menu according to actual need (status and
duration).
If the setting remains at 000, no output will be affected.
The setting takes effect only if the selected output (from 001 to xxx) will be
programmed as a
LINK
type. This function is very useful for technological
commands or direct auxiliary signals.
Step 5
Press
to return to the
WIRED ZONES
menu.
Then you can continue with programming other wired zones, or press
to return to the
WIRED ZONES
menu from where you can press
and
to move to the next menu or
press
to exit from the installer menu.
7.7 Key Type Zone
The key type zone is used as an auxiliary command to arm/disarm one or more areas. In the area
screen, the areas that the key zone will attempt to arm or disarm are defined. Having defined the
areas on which it will be able to act, the function parameter is proposed, which provides options as
below:
●
ON/OFF
◇
Modality
: Select
ON/OFF
option, the key zone is used as an
ON
and
OFF
command. The type
of arming will then be selected from
TOTAL
,
PARTITION 1
,
PARTITION 2
, and
PARTITION
1+2
.
◇
Trigger
: Select
IMPULSE
or
BISTABLE
(only for the
ON/OFF
command). This choice
determines whether the key zone acts with an
IMPULSE
or
BISTABLE
command (on each
N.C.
to
N.O.
change and vice versa).
◇
Arming
: Select
DELAYED OR IMMEDIATE
.
With delayed arming, the output time programmed for the area on the
AREAS
menu will
then follow. With immediate arming, the output time will not be taken into account and it will
be executed immediately.
◇
FORCED ARM
: Select
YES
or
NO
.
If
YES
is selected, the key zone will be armed even though there are open zones. If
NO
is
selected, the arming will take place only if all the Area Zones are ready for arming.
◇
Link: Set link output associated with the input.
●
ON ONLY, OFF ONLY
●
The settings
ON ONLY
and
OFF ONLY
use the
IMPULSE
type only.
◇
Modality
: Select
ON/OFF
option, the key zone is used as an
ON
and
OFF
command. The type
of arming will then be selected from
TOTAL
,
PARTITION 1
,
PARTITION 2
, and
PARTITION
1+2
.
◇
Arming
: Select
DELAYED OR IMMEDIATE
.
With delayed arming, the output time programmed for the area on the
AREAS
menu will
then follow. With immediate arming, the output time will not be taken into account and it will
be executed immediately.
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Page 137: ...User s Manual...