User’s Manual
V
to the controller label.
●
The controller is a class I electrical appliance. Make sure that the power supply of the controller is
connected to a power socket with protective earthing
●
The appliance coupler is a disconnection controller. Keep it at a convenient angle when using it.
Electrical Safety
Before acting on a system component, or while you are installing or servicing the controller, make
sure to disconnect both the primary (mains power) and secondary (battery) power supply of the
system. Also, to avoid damage from electrostatic discharge, handle the controller with care and
avoid any contact with its electronic components.
Power Supply
The power supply of the controller meets the EN 50131-6 standard, and performs the following
controls in compliance to the standard:
●
Every 24 hours, the status of the alternative power supply is checked. The battery test is executed
under load.
●
In the absence of mains voltage, the test is not executed.
●
Every 10 seconds, the output voltage is checked.
●
The output voltage is checked every 10 seconds.
●
The battery is disconnected if voltage drops below 10.8 V (protection against the deep
discharge).
Battery
The battery of the controller meets the EN 50131-6 standard, and performs the following controls in
compliance to the standard:
●
The controller must be equipped with a battery that has 12 V/12 Ah capacity.
●
We recommend using a FG 21201 battery.
●
The battery is designed with special lead calcium tin alloy grid that is built to resist corrosion and
provide a short recharge time.
●
The battery adopts VRLA AGM technology and uses low resistance high microporous fiberglass
separators.
●
The battery uses leak resistant post seal, faston, flag and threaded female, terminals with high
conductivity and maximum torque resistance.
●
The battery is designed with one-way safety relief valves that allow gas to escape, and prevent
the ingress of oxygen
●
The battery uses ABS plastic (from FGHL range flame retardant ABS plastic to IEC 707 FV0 and
UL94 FV0 - LOI greater than 28%).
●
The battery supports installation in any orientation, except being permanently inverted. The
batteries can only be replaced by qualified personnel.
●
The electrolyte is absorbed in fiberglass separators with 99% internal gas recombination
efficiency. Blocs are grants non-spillable and maintenance free, so their electrolytes do not
require topping up during its lifetime. Also, low self-discharge allows it a shelf life of 6 months.
Wire
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Page 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Page 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Page 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Page 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Page 137: ...User s Manual...