D-Link DXS-1210 Series User Manual
56
Figure 4.91 – L2 Features > L2 Multicast Control > IGMP Snooping > IGMP Snooping – Show Detail
Click the
Modify
button to edit the information in the following window:
Figure 4.92 L2 Features > L2 Multicast Control > IGMP Snooping > IGMP Snooping – Modify
The following parameters can be configured:
Fast Leave:
Select to enable or disable the IGMP snooping fast leave function.
Querier State:
Select to enable or disable the querier state.
Query Version:
Select the general query packet version sent by the IGMP snooping querier.
Query Interval (1-31744):
Enter the interval at which the IGMP snooping querier sends IGMP general query
messages periodically.
Max. Response Time (1-25):
Enter the maximum response time. The range is between 1 and 25 seconds.
Robustness Value (1-7):
Enter the robustness variable used in IGMP snooping.
Last Member Query Interval (1-25):
Enter the interval at which the IGMP snooping querier sends IGMP
group-specific or group-source-specific query messages.
Click the
Apply
button to save your settings.