1. Position the XP4000 Series unit so that the rear panel is facing you.
Choose an available slot. An available slot will have a solid panel cover-
ing the opening to the unit, with no connectors showing through it.
NOTE:
For front access models, the LCI module, located to the far left
of the unit (viewed from rear), is covered by a solid panel but
IS NOT
an available slot. Only the LCI module can be installed in this slot.
2. Remove the panel covering the available slot by unscrewing the two
Phillips-head screws on the rear of the unit that hold the panel in place.
3. Slide the new user interface (XPDU/XPLU) module gently into the open
slot of the XP4000 Series unit until the 62-pin connector lines up flush
with the back of the unit. See the diagram below.
4. Retighten the holding screws completely. DO NOT overtighten.
5. Fill out the XPDU/XPLU Configuration Chart in Appendix A for each
module as you install it.
Follow the above procedure for every XPDU/XPLU module in your system.
Installing the
Secondary
Console
Modules (XPDU
and XPLU)
The XPDU and XPLU modules are installed identically. There are no DIP
switches or jumpers to configure on either module
Secondary
Console
Modules
A secondary console module is one of the two types of user modules. While
the primary console peripherals connect through the front panel of the unit
(discussed in the previous section), secondary console modules have the
peripherals connected through the rear of the module. Currently we offer
versions with on-screen display capabilities (XPDU) and without (XPLU).