62 of 64
CORRADI S.R.L.
- INSTALLATION MANUAL - PERGOTENDA ® MAESTRO
REV.1 - 11.2019
TAB.3 TRACTION EFFORT ON FOOT DOWEL - PERGOTENDA MAESTRO 3G
Maximum effort* [daN=1Kg] on single traction dowel considering 4 bolts per feet
and a 300 cm high structure. Values relating to the corresponding classes specified in table 1.
** The indicated values must be considered in combination to a shear effort on the single dowel
equal to 120 daN
.
Maximum effort** [daN=1Kg] on single traction dowel considering 4 bolts per foot and a 300 cm high
structure. Values relating to the corresponding classes specified in table 1.
2250 daN
** The indicated values must be considered in combination to a shear effort on the single dowel
equal to 240 daN
TABLES
Wind resistance classes according to EN 13561: 2015
Cover
Class 3= 110 N/sq.m = 47 km/h)
Side closures
Side closures= 110 N/sq.m =
47 km/h
(attention: The value must be compared with the resistance value of the side closure)
TAB.2 TRACTION EFFORT ON FOOT DOWEL - PERGOTENDA MAESTRO 2G
Maximum effort* [daN=1Kg] on single traction dowel considering 4 bolts per feet
and a 300 cm high structure. Values relating to the corresponding classes specified in table 1.
*The indicated values must be considered in combination to a shear effort on the single dowel equal
to 120 daN
.
Maximum effort** [daN=1Kg] on single traction dowel considering 4 bolts per foot and a 300 cm high
structure. Values relating to the corresponding classes specified in table 1.
2250 daN
** The indicated values must be considered in combination to a shear effort on the single dowel
equal to 240 daN
Width (cm)
300
400
550
pr
ojec
tion (cm)
300
720
870
780
400
720
870
780
500
720
870
780
600
720
870
980
700
720
870
1200
Width (cm)
400
500
600
700
pr
ojec
tion (cm)
300
960
960
960
960
400
960
960
1090
960
500
960
960
1090
1110
600
960
960
1100
1310
700
960
960
1320
1390