50 of 64
CORRADI S.R.L.
- INSTALLATION MANUAL - PERGOTENDA ® MAESTRO
REV.1 - 11.2019
Fig. 66
- On the structure left and right side, use self-drilling screws to fix the angle bar (
A
) and (
B
) to the crossbeam (
C
);
- fix plates (
A
), previously screwed to the structure, to the wall using suitable fixing systems (
D
) (not supplied by Corradi);
- use the upper profile (
E
) to close, and use the self-drilling screws to fix it to the structure;
- apply silicone along the entire profile close to the wall.
18 WALL-MOUNTED OPTION WITH PILLARS
D
A
A
B
C
E