72
14. Signals of the smoke detector
Operating status
optical, LED
acoustic/signal tone
Normal operation
Flashes every 32 sec.
–
Function test ok
Flashes every 0.5 sec.
Signal tone every 0.5 sec.
Smoke alarm
Flashes every 0.5 sec.
Signal tone every 0.5 sec.
Battery weak
Flashes every 32 sec.
Simultaneously
with the LED
a chirp sound is emitted
Sensitivity
Flashes every 32 sec.
alternately
with the LED
deteriorated
a chirp sound is emitted
15. Replacing the battery
We recommend using high-quality alkaline batteries only.
For reasons of safety, replace batteries every 12 months. The "old" batteries can then be
used in non-critical devices (e.g. clocks, remote controls etc.).
a) Alarm dialler "AW50"
If the alarm dialler has set off the voice message "Battery empty", then replace all the batteries of the
alarm dialler with new ones.
To do this, open the battery compartment on the rear of the appliance, remove the spent batteries
and insert four new miniature (AA) batteries, observing correct polarity (plus/+ and minus/-). Also pay
attention to the markings in the battery compartment. Close the battery compartment.
b) "KeyMatic CAC"
Please note the operating instructions for "KeyMatic CAC".
Summary of Contents for 750945