Volatile trap
(only in conjunction with aftercooler) - The volatile trap is recommended if
drying materials that produce volatile that condense into a waxy or oily residue and/or if
the material contains excessive fines.
•
Precooler
- The precooler reduces the temperature of air flow after the desiccant wheel
and before the process heater.
•
Filter check
- The Filter check sensor will activate a passive alarm when the process
filter is clogged or needs to be replaced.
•
Heater current monitor
- The heater current monitor measures the total amperage
across both the process and regeneration heaters and the pre-determined power consump-
tion values for the blowers and the control.
•
CFM monitor
- The CFM monitor measures the cubic feet per minute of airflow across
the inlet/outlet of the process blower.
•
DeviceNet or SPI communications
- Allows the dryer to be networked to industrial con-
trol systems. DeviceNet communications are standard. Alternate communications are
available.