DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Specifications
Revision 2
2–2
2.1.3
Mean Time Between Failures (MTBF)
•
49,740 hrs as calculated
•
>100,000 hrs based on field experience
2.1.4
Temperature Range
•
Operating:
32° to 122° F (0° to 50° C)
•
Storage:
-4° to 158 F° (-20° to 70° C)
2.1.5
Humidity (Non-condensing)
•
Operating:
0 to 95% Relative maximum
•
Storage:
99% maximum
2.1.6
Altitude
10,000 ft Mean Sea Level (MSL)
2.1.7
Front Panel Features
2.1.7.1
Sample Test Point Connectors
•
STANDARD:
o
(1X) ‘RF’ – Type ‘SMA’female, -20 dBc nominal
o
(1X) ‘IF’ – BNC female, -20 dBc nominal
•
OPTIONAL:
RF LO monitor available (0 dBm nominal – replaces ‘RF’ sample point)
2.1.7.2
LED Monitoring
Six Status LEDs:
•
POWER ON (GREEN)
•
OUTPUT ENABLE (AMBER)
•
REMOTE (AMBER)
•
ON LINE (AMBER)